6-1. EXECUTING IOP MEASUREMENT

In order to execute IOP measurement, the following standard
procedures must be followed.
(1)
In standby mode, press
[POWER]
to enter Remocon Diagnosis Mode.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version information
5. Video Level Adjustment
Model
: xxx xxx xxx
IF-con Ver
: xxx
Syscon Ver : xxx
Select "2. Drive Manual Operation" by pressing the 2
(2)
key on the remote commander. The screen will appear as
below.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
0. Return to top Menu
TE
L 13942296513
(3)
Select "3. Manual Adjustment" by pressing the 3 key on
the remote commander. The screen will appear as below.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(4)
Select Iop by pressing 6 key on the remote commander.
www
.
http://www.xiaoyu163.com
[TOP MENU]
[CLEAR]
,
x
ao
u163
y
i
http://www.xiaoyu163.com
SECTION 6

TEST MODE

2 9
8
(5)
Wait until a hexadecimal number appear.
1. Track Balance Adjust:
2. Track Gain Adjust:
,
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. ED:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
$4 Change Value
[RETURN] Return to previous menu
(6)
Convert data from hexadecimal to decimal.
(7)
Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
Press [RETURN] to return back to previous menu.
(8)
(9)
Press - to return to Top Menu and power OFF the DVD
Player.

6-2. EMERGENCY HISTORY CHECK

Information of Emergency History.
Q Q
3
6 7
1 3
(1)
In standby mode, press
[POWER]
(2)
Select "3. Emergency History".
Emg. History Check
Laser Hours
1. 01 05 04 04
00 00 00 00
2. 02 02 01 01
00 00 00 00
[Next] Next Page [Prev] Prev Page
(3)
Laser Hours
DVD Laser ON time. (Total ON time)
CD Laser ON time. (Total ON time)
(4)
Emergency History
The history information from last "1" to "10" can be
scrolled with [NEXT] key or [PREV] key.
(5)
Error code
Example of Error code
1. 01 05 04 04
00 00 00 00
.
6-1
9 4
2 8
Manual Adjust
1 5
0 5
8
2 9
9 4
[TOP MENU]