Sony DVP-NS355 Service Manual page 61

Cd/dvd player with remote control rmt-d165a/rmt-d165p/rmt-d166p
Hide thumbs Also See for DVP-NS355:
Table of Contents

Advertisement

(3)
Select “5. MIRR time Adjust”.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time Adjust
0. Return to Top Menu
(4)
Select “5. Default set MIRR time”.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] tray close
[0] Return to previous menu
(5)
Select “3. Threshold”.
(6)
Confirm the number. If it is 75, go to next step. If it is any
other value, return to step 4.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check:
3. Threshold: 75
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [Close] tray close
[0] Return to previous menu
(7)
Push “Open/Close” key to eject tray.
(8)
Insert Test Disc HLX-504 into tray.
(9)
Push “Open/Close” key to close tray.
(10)
Push “2. DVD MIRR time Check”.
(11)
Wait for HEX number to display.
(12)
Confirm the number, if XX is 28 ~ 70, proceed with next
step. If no, return to 8.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: xx xx
3. Thereshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] tray open [close] tray close
[0] Return to previous menu
(13)
Push “4. Save to EEPROM”.
(14)
Confirm the same values are displayed. If it is not same,
return to step 7.
MIRR time adjustment Menu
1. CD MIRR time Check:
2. DVD MIRR time Check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu
(15)
Push “Open/Close” key to eject tray.
(16)
Take out HLX-504 and insert Test Disc YEDS-18 into
tray.
(17)
Push “Open/Close” key to close tray.
(18)
Push “1. CD MIRR time check”.
(19)
Wait for HEX number to display.
(20)
Confirm the number, if YY is 5A ~ E8, proceed with next
step. If no, return to 15.
MIRR time adjustment Menu
1. CD MIRR time Check: yy YY
2. DVD MIRR time Check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu
(21)
Push “4. Save to EEPROM”.
(22)
Confirm the same values are displayed. If it is not the
same, return to step 15.
MIRR time adjustment Menu
1. CD MIRR time check: YY YY
2. DVD MIRR time check: XX XX
3. Threshold:
4. Save to EEPROM:
5. Default set MIRR time:
[Open] Tray open [close] tray close
[0] Return to previous menu
(23)
Push “Open/Close” key to eject tray.
(24)
Remove Test Disc YEDS-18 from tray.
(25)
Push “Open/Close” key to close tray.
(26)
Press “0” to return to the Drive Manual Operation menu.
(27)
Press “0” to return to the Remocon Diagnosis Menu.
(28)
Press power button to switch OFF set.
6-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents