Sharp R-370EK Service Manual page 20

Hide thumbs Also See for R-370EK:
Table of Contents

Advertisement

R- 370EK
R- 37 0ES
PROCEDURE
LETTER
STEPS
5) Make a visual inspection of the varistor. Check
for burned damage and examine the
transformer with a tester for the presence of
layer short-circuit (check the primary coil
resistance which is approximately 212
10%). If any abnormal condition is detected,
replace the defective parts.
6) Reconnect all leads removed from
components during testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the
outer case is installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if the indicator does not light up after above check and
repairs are finished.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) To discharge the high voltage capacitor, wait for 60 seconds.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
insulation tape.
6) After that procedure, re-connect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
STEPS
8) Disconnect the power supply cord, and then remove outer case.
9) Open the door and block it open.
10) To discharge the high voltage capacitor, wait for 60 seconds.
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
N
AH SENSOR TEST
Checking the initial sensor cooking condition
WARNING : The oven should be fully assembled before following procedure.
(1) The oven should be plugged in at least two minutes before sensor cooking.
(2) Room temperature should not exceed 95˚F (35˚C).
(3) The unit should not be installed in any area where heat and steam are generated. The unit should
not be installed, for example, next to a conventional surface unit. Refer to the "INSTALLATION
INSTRUCTIONS" of the operation manual.
(4) Exhaust vents are provided on the back of the unit for proper cooling and air flow in the cavity. To
permit adequate ventilation, be sure to install so as not to block these vents. There should be some
space for air circulation.
TEST PROCEDURES
OCCURRENCE
1
Only pattern at "a" is broken.
2
Pattern at "a" and "b" are broken.
OCCURRENCE
The rated AC voltage is not present between
1
the normal open terminal of the relay RY1 and Check supply voltage and oven power cord.
the normal open terminal of the relay RY2.
The rated AC voltage is present at primary
2
side of low voltage transformer.
COMPONENT TEST
CAUSE OR CORRECTION
*Insert jumper wire J1 and solder.
*Insert the coil RCILF2003YAZZ between "c" and "d".
CN - A
c
CAUSE OR CORRECTION
Low voltage transformer or secondary circuit defective.
Check and repair.
18
1
2
a
d
(J1)
b