Mechanical disassemblies

Disassemble should be made following procedures in numerical order.
Following steps show the basic procedures, therefore unnecessary step may be ignored.
Caution:
The parts and screws should be placed exactly the same position as the original otherwise it may cause lose of
performance and product safety.
Hook
A
A
C
(a)
C
(a)
C
C
B
C
B
C
B
B
C
C
C
Cabinet front
C
C
Cabinet front bottom
1.
and Cabinet-front removal.
1. Remove 2 screws-A. Push part(a) and pull
the Cabinet-front-top up.
2. Remove 4 screws-B and remove the Cabinet
front bottom.
3. Remove 11 screws-C and remove the
Cabinet front.
Refer to Lens replacement and installation
manual.
2.
Remove 8 screws and remove the Cabinet -
top.
-10-
Cabinet-front-top,
Cabinet-front-bottom
Note :
Be careful not to damage Hook.
The cabinet-front-top is being
fixed with cabinet-front-bottom by
hook.
Cabinet-top removal.