4.7.4.4
CONVERGENCE ADJUSTMENT
Measuring
Item
instrument
CONVERGENCE
Signal
PHASE
generator
[check]
Remote
control unit
Item No.
CPA04
CPA05
CPA06
CPA07
CPA08
CPA09
CPA10
CPA11
REMOTE CONTROL KEY POSITION
INPUT key
CPA
CCA
**
**
CBA
CDA
**
SELECT key
For adjusting color change
MUTING key
For storing adjustment
data in memory
CH+ / CH- keys
Item No. change
[CH+] : up
[CH - ] : down
VOL+ / VOL- keys
Setting value change
[VOL+] : up
[VOL- ] : down
OK key
For display color change
Two colors : adjusting color + green
Three colors : RGB
Test point
Adjustment part
[6.CONVER A]
CPA04 : TPOV OFST
CPA05 : FINEP
CPA06 : STARTLIN A
CPA07 : STARTLIN B
CPA08 : CAU H2
CPA09 : COARS OFST
CPA10 : V1OFSTA
CPA11 : V1OFSTB
Initial setting
Item name
value
TPOV OFST
0
FINEP
1245
STARTLIN A
56
STARTLIN B
-1
CAU H2
0
COARS OFST
-50
V1OFSTA
7
V1OFSTB
0
Table-1
**
MULTI SCREEN
TWIN
INDEX
C.C.
FREEZE SWAP
SELECT
INPUT
SOUND
TUNE
ASPECT
LIGHT
OK
BACK
RM-C1257G
Description
NOTE:
Be sure to make it the value of Table-1. Supposing data
differs, correct to the value of Table-1.
When data is corrected (when the [MUTING] key is
pushed), it is necessary to perform an AUTO
CONVERGENCE PRESET, after a convergence
adjusts exactly.
(1) Receive NTSC crosshatch signal.
(2) Select 6.CONVER A from SERVICE MENU.
(3) Select < CPA > item with [INPUT] key.
(4) Check and set data that < CPA04 > ~ < CPA11> are
same value as table1.
(5) Press [MUTING] key to memorize the set values.
(No.YA097)1-57