CALIBRATION PROCEDURES
9.4.4
Charging Calibration
1.
Switch on PSU2 and set the voltage to 5.8 V. Connect Cable 2 to the connector of Cable 1.
2.
Carry out the instructions described in the main dialogue window.
3.
When prompted, measure the RF Adaptor / Baseband Jig voltage by connecting a voltmeter to the terminals on the RF
Adaptor / Baseband Jig.
4.
If at any time the message "Charging Cal failed", the calibration procedure has failed. Check all test equipment
connections and that the correct resistor has been selected before suspecting a problem with the handset. Further
information may be displayed in the dialogue window.
5.
When the message "Charging Cal Done" is displayed in the dialogue window, the calibration procedure has been
completed.
9.5. Camera Calibration
Currently there are no camera calibration procedures for this product.
Issue 1
Revision 1
Section 9
– 56 –
PMCD030901C8
Service Manual