CHAPTER 1 GENERAL ADJUSTMENTS SAFETY INSTRUCTIONS WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRE- CAUTION” AND “PRODUCT SAFETY NOTICE” INSTRUCTIONS BELOW. X-RAY RADIATION PRECAUTION 1. Excessive high voltage can produce potentially hazard- 2. The only source of X-RAY RADIATION in this TV ous X-RAY RADIATION.
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRE- CAUTION” AND “PRODUCT SAFETY NOTICE” ON PAGE 3 OF THIS MANUAL. SET-UP ADJUSTMENT The following adjustments should be made when a complete realignment is required or a new picture tube is installed. Perform the adjustments in order as follows : 1.
Page 5
CONVERGENCE ADJUSTMENTS CIRCUMFERENCE CONVERGENCE ADJUSTMENT NOTE: Before attempting any convergence adjustments, the 1. Loosen the clamping screw of deflection yoke slightly to receiver should be operated for at least fifteen min- allow the yoke to tilt. utes. 2. Temporarily put a wedge as shown in figure 1. (Do not remove cover paper on adhesive part of the wedge.) CENTER CONVERGENCE ADJUSTMENT 3.
Page 6
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE “X-RAY RADIATION PRECAUTION”, “SAFETY PRECAU- TION” AND “PRODUCT SAFETY NOTICE” ON PAGE 3 OF SERVICE MANUAL. SET-UP ADJUSTMENT (FOR FLAT TUBE) The following adjustments should be made when a complete realignment is required or a new picture tube is installed. Perform the adjustments in order as follows : 1.
Page 7
(5)Adjust the sub-4-pole magnets only in case there is any deviation of Xv bow-shaped convergence. (To be usually set at the initial position) Align both sides with the sub-4-pole magnets and minimize the deviation of blue and red with the main 4-pole magnets. Xv bow-shaped deviation of convergence red/blue blue...
SERVICE MODE 1. ENTERING TO SERVICE MODE 3) While pressing the o button, 2) Press o button again to 1) Press o button once on keep pressing. press MENU button on TV set. Remote Control. Item Data Mute or (Service mode display) 2.
Page 9
4. SELECTING THE ADJUSTING ITEMS 1) Every pressing of CHANNEL s button in the service mode changes the adjustment items in the order of table-2. (t button for reverse order) Refer to table-2 for preset data of adjustment mode. (See SETTING & ADJUSTING DATA on page 15) 5.
Page 10
8. SELF DIAGNOSTIC FUNCTION 1) Press “9” button on Remote Control during display of adjustment menu in the service mode. The diagnosis will begin to check if interface among IC’s are executed properly. 2) During diagnosis, the following displays are shown. Indicated color of mode now selected : Green and Red Indicated color of other modes : White...
DESIGN MODE 1. ENTERING TO DESIGN MODE 1) Select the Service mode. 2) While pressing o or CALL button on 3) Press MENU button on TV. Remote and press MENU button on TV. ITEM Press DATA Press (Design mode) (Adjustment mode) When QA02 is initialized, items “OPT0”, “OPT1”...
ELECTRICAL ADJUSTMENTS ITEM ADJUSTMENT PROCEDURE FOCUS VR ADJ 1. Enter the service mode, then select any register item. 2. Press the TV/VIDEO button on the Remote until the black cross-bar pattern ap- pears on the screen. 3. Adjust the FOCUS control (on T461) for well defined scanning lines on the picture screen.
Page 13
ITEM ADJUSTMENT PROCEDURE WHITE BALANCE 1. Set Contrast to 40, and brightness to +20 by picture control. ADJUSTMENT 2. Receive the Black and White pattern. 3. Select RCUT, GCUT and BCUT with CHANNEL s, t buttons, to set individual • CUTOFF ADJUSTMENT values to Initial reference data, and to set GDRV and BDRV to Initial reference (RCUT)
CIRCUIT CHECK HIGH VOLTAGE CHECK CAUTION: There is no HIGH VOLTAGE ADJUSTMENT on this chassis. Checking should be done following the steps below. 1. Connect an accurate high voltage meter to the second anode of the picture tube. 2. Turn on the receiver. Set the BRIGHTNESS and CONTRAST controls to minimum (zero beam current). 3.
CHAPTER 2 SPECIFIC INFORMATIONS SETTING & ADJUSTING DATA SAFETY INSTRUCTIONS 32" 28" HIGH VOLTAGE AT ZERO BEAM: 31.7 kV 31.4 kV MAX HIGH VOLTAGE: 35.0 kV 33.0 kV AC VOLTAGE 220~240 V Table-1 SERVICE MODE ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE: Item Item Adjustment...
LOCATION OF CONTROLS Front REMOTE SENSOR POSITION UP POSITION DOWN VIDEO-3 VOLUME UP HEAD PHONE VOLUME DOWN MENU POWER INDICATOR (RED) Rear terminals AERIAL TERMINAL VIDEO-2 (21PIN S-VIDEO/AV) VIDEO-1 (21PIN S-VIDEO/AV) – 16 –...
Page 17
Remote Controller DISPLAY TELETEXT MUTE DISPLAY CALL/INDEX (TELETEXT) POWER-ON/STANDBY DISPLAY SIZE HOLD A WANTED PAGE REVEAL CONCEALED TEXT SELECT A PAGE NUMBER BUTTONS PREVIOUS PROGRAMME VIDEO INPUT SELECT TELETEX CONTROL BUTTONS ON-SCREEN MENU EXIT MENU SELECT MENU VOLUME LEVEL UP/DOWN POSITION/TELETEXT PAGE UP/DOWN (NOT USED FOR THIS MODEL)
· · · · · The part number must be used when ordering parts, in order to assist in processing, be sure to include the Model number and Description. · · · · · The PC board assembly with mark is no longer available after the end of the production. Model : 28Z33B/32Z33B Capacitors ..... CD : Ceramic Disk PF : Plastic Film EL : Electrolytic Resistors ....
Page 19
Location Parts No. Descriptiopn Location Parts No. Descriptiopn C512 24100104 CERAMIC CHIP, 25V F 0.1UF Z C931 24214101 CERAMIC DISC, 500V B 100PF K C513 24100104 CERAMIC CHIP, 25V F 0.1UF Z C4401 24109153 CERAMIC CHIP, 50V B 0.015UF K C514 24794101 ELECTROLYTIC, 16V 100UF M C4402...
Page 20
Location Parts No. Descriptiopn Location Parts No. Descriptiopn RESISTORS R375 24011223 CHIP, METAL FILM, 1/20W 22K OHM J R101 24553223 OXIDE METAL FILM, 1W 22K OHM J R376 24011104 CHIP, METAL FILM, 1/20W 100K OHM J R102 24011103 CHIP, METAL FILM, 1/20W 10K OHM J R377 24011563 CHIP, METAL FILM, 1/20W 56K OHM J R103...
Page 21
Location Parts No. Descriptiopn Location Parts No. Descriptiopn R818 24019463 METAL PLATE RK99 2W R22 J RA05 24011103 CHIP, METAL FILM, 1/20W 10K OHM J R819 24310829 OXIDE METAL FILM, 1/2W 8.2 OHM J RA06 24011102 CHIP, METAL FILM, 1/20W 1K OHM J R822 24552103 OXIDE METAL FILM, 1/2W 10K OHM J RA07...
SCHEMATIC DIAGRAM MODEL : 28Z33B/32Z33B WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL. CAUTION: The international hazard symbols " " in the schematic diagram and the parts list designate components which have special characteristics important for safety and should be replaced only with types identical to those in the original circuit or specified in the parts list.