Service Adjustment - Sharp 32C240 Service Manual

Sharp color television service manual
Hide thumbs Also See for 32C240:
Table of Contents

Advertisement

32C240
32C241
RF AGC Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "R01".
3. Set the data value to point where no noise or beat
appears.
4. Select another channel to confirm that no noise or
beat appears.
Note 1 : You will have to come out of the service
mode to select another channel.
Note 2 : Setting the data to "00" will produce a black
raster.
Screen Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set the data value to "00" to
set the color level to minimum. (Record original data
code under adjustment "V03" before changing) You
may skip this step, if you selected a B/W picture or
monoscope pattern.
3. Select the service adjustment "V11" and adjust the
data value to "01", this turn off the luminance signal
(Y-mute).
4. Adjust the master screen control until the raster
darkens to the point where raster is barely seen.
5. Adjust the service adjustments "V06" red, "V07" green
and "V08" blue to obtain a good grey scale with
normal whites at low brightness level.
6. Select the service adjustment "V11" and reset data
to "00". Select the service adjustment "V03" and reset
data to obtain normal color level.
7. For component input, the data value of "V46" red,
"V47" green and "V48" blue is adjusted to follow the
data value of "V06", "V07" and "V08" respectively.
8. Reset the master screen control to obtain normal
brightness range.

SERVICE ADJUSTMENT

10
White Balance Adjustment
1. Receive a good local channel.
2. Enter the service mode and select the service
adjustment "V03" and set to "00" (minimum
color)(Record original data code under adjustment
"V03" before changing). "V03" does not have to be
adjusted, if you selected a B/W picture or monoscope
pattern.
3. Alternately adjust the service adjustment data of "V09"
and "V10" until a good grey scale with normal whites
is obtained. (RF Input)
4. For component input, the data value of "V49" and
"V50" is adjusted to follow the data value of "V09"
and "V10" respectively.
5. Select the service adjustment "V03" and reset data
to obtain normal color level.
Sub-picture and Sub-Bright Adjustments
1. Receive the window pattern signal.
RF INPUT (TU51)
2. Get into service adjustment data "V01" and "V05" and
set the luminance as shown in figure "A" and "B" as
below respectively.
COMPONENT INPUT
3. Get in service adjustment data "V42" and "V45" and
set the luminance as shown in figure "A" and "B" as
below respectively.
A
LUMINESCENCE CONFIRMATION
2
A: 92 10cd/m
B: 1.1 0.5cd/m
2