3. Setting Number of Cool/Heat Stages (T8024F
Only).
a. Press
to display number of cool stages.
b. Press
to change number of cool stages.
c. Press
to display number of heat stages.
d. Press
to change number of heat stages.
4. Setting Heat Cycle Rate (see Table 2) for the cycle
rate options and equipment.
a. Press the
key to display the current heat
cycle rate setting of 1,3, 4, 5, 6, 9, or 12 cph.
NOTE: If thermostat is set to operate two stages of heat
(T8024 only), both stages operate at the
selected cycle rate.
b. To change the heat cycle rate, press the
until your choice of 1, 3, 4, 5, 6, 9, or 12 is dis-
played. See Table 2.
T8001F, T8024F FLUSH MOUNT PROGRAMMABLE THERMOSTAT
c. Press the
configuration default.
M20216
d. Press the
rithm to C1 or C3.
M20215
e. Press the
(CC) is displayed. A typical example is shown,
but CC varies by model. (This information is for
factory use only.)
M20217
5. Exit Installer Setup.
M20218
a. Press the
to normal operation.
M12589A
Steam, gravity
Hydronic heat, condensing gas
a
furnaces
key
Gas or oil forced air
Electric heat
Special applications
a
High efficiency furnace (90+).
b
Refer to the equipment manufacturer's instructions.
5
key to display control algorithm
key again to change control algo-
C1 = Standard control algorithm.
C3 = Aggressive control algorithm (can
cause overshooting).
key again. Current configuration
key to save all changes and return
Table 2. Heating Cycle Rate
System
b
M12588A
M14691
M14692
PM
M12590A
Cycles Per Hour
1
3
6
9
4, 5, 12