Chapter 11. Component Replacement And Adjustment Procedure Warnings; And Adjustment Procedure 1] Warnings; Component Replacement And - Sharp R-305MR Service Manual

Hide thumbs Also See for R-305MR:
Table of Contents

Advertisement

R305MR
CHAPTER 11.
R305MR
COMPONENT REPLACEMENT AND ADJUSTMENT PROCE-
DURE
[1] WARNINGS
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result
in severe, possibly fatal, electric shock.
(Example)
High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..
Avoid possible exposure to microwave energy. Please follow the instructions below before
WARNING:
operating the oven.
1. Disconnect the power supply cord.
2. Make sure that a definite "click" can be heard when the
microwave oven door is unlatched. (Hold the door in a
closed position with one hand, then push the door open
button with the other, this causes the latch leads to rise, it
is then possible to hear a "click" as the door switches
operate.)
3. Visually check the door and cavity face plate for damage
(dents, cracks, signs of arcing etc.).
Carry out any remedial work that is necessary before operat-
ing the oven.
Do not operate the oven if any of the following conditions exist;
1. Door does not close firmly.
To prevent an electric shock, take the following precau-
tions.
1. Before wiring,
1) Disconnect the power supply cord.
2) Open the door block it open.
3) Discharge the high voltage capacitor and wait for 60
seconds.
2. DonÕt let the wire leads touch to the following parts;
1) High voltage parts:
Magnetron, High voltage transformer, High voltage
capacitor and High voltage rectifier assembly.
2) Hot parts:
Oven lamp, Magnetron, Power transformer and Oven
cavity.
Please refer to "OVEN PARTS, CABINET PARTS, CONTROL PANEL PARTS, DOOR PARTS", when carrying out any of the following removal proce-
dures:
WARNING AGAINST HIGH VOLTAGE:
WARNING FOR WIRING
11 – 1
Service Manual
2. Door hinge, support or latch hook is damaged.
3. The door gasket or seal is damaged.
4. The door is bent or warped.
5. There are defective parts in the door interlock system.
6. There are defective parts in the microwave generating
and transmission assembly.
7. There is visible damage to the oven.
Do not operate the oven:
1. Without the RF gasket (Magnetron).
2. If the wave guide or oven cavity are not intact.
3. If the door is not closed.
4. If the outer case (cabinet) is not fitted.
3) Sharp edge:
Bottom plate, Oven cavity, Waveguide flange and
other metallic plate.
4) Movable parts (to prevent a fault)
Fan blade, Fan motor, Turntable motor, Switch, Switch
lever, Open button.
3. Do not catch the wire leads in the outer case cabinet.
4. Insert the positive lock connector until its pin is locked and
make sure that the wire leads do not come off even if the
wire leads are pulled.
5. To prevent an error function, connect the wire leads
correctly, referring to the Pictorial Diagram.