I: Noise Filter Test; J: Touch Control Panel Assembly Test - Sharp R-305MR Service Manual

Hide thumbs Also See for R-305MR:
Table of Contents

Advertisement

If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must be replaced with "monitor fuse and monitor
switch assembly" part number FFS-BA033WRKZ or FFS-BA037WRKZ, even if the monitor switch operates normally. The monitor fuse and moni-
tor switch assembly is comprised of a 20 ampere fuse and switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.

[10] I: NOISE FILTER TEST

1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the lead wires from the terminal the noise filter. Using an ohmmeter, check between
the terminals as described in the following table. If incorrect reading are obtained, replace the
noise filter.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
MEASURING POINT
Between N and L
Between terminal N and WHITE
Between terminal L and RED

[11] J: TOUCH CONTROL PANEL ASSEMBLY TEST

The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore, unlike conventional microwave ovens, proper
maintenance cannot be performed with only a voltmeter and ohmmeter. In this service manual, the touch control panel assembly is divided into two
units, Control Unit and Key Unit, and also the Control Unit is divided into two units, CPU Unit and Power Unit, and troubleshooting by unit replacement
is described according to the symptoms indicated.
Before testing,
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
1. Key Unit
NOTE:
1) )Re-install the outer case (cabinet).
2) Reconnect the power supply cord after the outer case is installed.
3) Run the oven and check all functions.
The following symptoms indicate a defective key unit.
a) When touching the pads, a certain pad produces no signal at all.
b) When touching a number pad, two figures or more are displayed.
c) When touching the pads, sometimes a pad produces no signal.
2. Control Unit.
The following symptoms indicate a defective control unit.
1) In connection with pads.
a) When touching the pads, a certain group of pads do not produce a signal.
b) When touching the pads, no pads produce a signal.
2) In connection with indicators
a) At a certain digit, all or some segments do not light up.
b) At a certain digit, brightness is low.
c) Only one indicator does not light.
INDICATION OF OHMMETER
Open circuit.
Short circuit.
Short circuit.
8 – 4
NOISE FILTER
N
FUSE 20A
LINE CROSS CAPACITOR
0.22μF / AC 250V
NOISE SUPPRESSION COIL
LINE BYPASS
LINE BYPASS
CAPACITOR
CAPACITOR
0.0033μF / AC 125V
0.0033μF / AC 125V
WHITE
R305MR
L
RED

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents