Calibration - Optoma ZW210ST Serivce Manual

Hide thumbs Also See for ZW210ST:
Table of Contents

Advertisement

4-3-5 SD Card /U disk Test
Procedure
4-3-6 3D Test
Procedure
Inspection item
Inspection Distance
Criteria

4-4 Calibration

1. Fan Calibration
To store the value of fan in main board, after replacing main board, blower
or upgrading the firmware, the "Fan calibration" is needed:
Procedure
- Test equipment: SD Card/U disk
- Test signal:ZW210ST 1280x800@60Hz
ZX210ST 1024x768@60Hz
- Turn on the projector and plug SD Card
projector.
- Ensure the image and audio are well
performed and the color can not discolor.
- Test equipment: DVD Player
-Test signal:ZW210ST 1280x800@60Hz
ZX210ST 1024x768@60Hz
- 3D test
- < 6M
- The image should not appear noise, flicker, shadow,
shocking, abnormal color.
- Press the "left" button and hold on, then press
the "power" button, release the "left" button until
the "Optoma" logo appeared .
- Get into Service Mode to check the fan speed has
been recorded.
SD Card/U disk into the
ZW20ST/ZX20ST
Confidential
4-8