This projector provides a function to control and monitor the projector's operations by using the RS-232C serial port.
Operation
1
Connect a RS-232C serial cross cable to CONTROL PORT
on the projector and serial port on the PC. (See p.19)
2
Launch a communication software provided with PC and
setup the communication condition as follows:
Baud rate
Parity check
Stop bit
Flow control
Data bit
Note:
The default of the baud rate is set to 19200 bps. If an
error occurs in the communication, change the serial port
and the communication speed (baud rate).
3
Type the command for controlling the projector and then enter
the "Enter" key.
Example
When you want to change the input to INPUT 2, Type 'C' '0' '6'
'Enter'.
Note:
Enter with ASCII 64-byte capital characters and one-byte
characters.
86

Serial Control Interface

: 9600 / 19200 bps
: none
: 1
: none
: 8