Self Diagnosis Function; Diagnostic Test Indicators - Sony KP-FS57M31 Service Manual

Ag-3x chassis
Hide thumbs Also See for KP-FS57M31:
Table of Contents

Advertisement

The unit in this manual contain a self-diagnostic function. If any error occurs, the STANDBY/TIMER lamp will automatically
begin to flash.
The number of times the lamp flashes translates to a probable source of the problem. A definition of the STANDBY/TIMER
lamp flash indicators is listed in the instruction manual for the user's knowledge and reference. If an error symptom cannot be
reproduced, the remote commander can be used to review the failure occurrence data stored in memory to reveal past problems
and how often these problems occur.

1-1. DIAGNOSTIC TEST INDICATORS

When any error occurs, the STANDBY/TIMER lamp will flash a set number of times to indicate the possible cause of the
problem. If there is more than one error, the lamp will identify the first of the problem areas.
Result for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a "0".
No. of times
Diagnostic
Item
STANDBY/TIMER
Description
lamp flashes
Does not light
• Power does not
turn on
2 times
• +B overcurrent
(OCP)
3 times
• +B overvoltage
(OVP)
4 times
• Vertical deflection
failure
5 times
• White balance
failure
(no PICTURE)
6 times
•Horizontal deflection
failure or +5v down
or High Voltage
failure
7 times
• Audio Protection
• Micro reset
Note 1 : Refer to screen (G2) adjustment in section 3-2 of this manual.
SECTION 1

SELF DIAGNOSIS FUNCTION

Self-diagnostic
display/
Probable Cause Location
Diagnostic result
• Power cord is not plugged in.
• Fuse (F6701) is burned out.
(G board)
• H. OUT Q8024 is shorted.
002:000 or
• H. LIN Q8027 is shorted.
002:001 ~ 255
(D board)
003:000 or
• HV OUT Q8043 is shorted.
003:001 ~ 255
• PH6001 faulty.
• +19V is not supplied.
(G board)
004:000 or
• V. OUT IC8003 faulty.
(D board)
004:001 ~ 255
• G2 is improperly adjusted.
005:000 or
(Note 1)
005:001 ~ 255
• CRT problem.
• Video OUT IC9101 (CR
board), IC9201 (CG board),
IC9001 (CB board) are faulty.
• IC8306 (J board) and IC4300
(E board) are faulty.
• No connection E board to CR
board.
• IC6502 (G board) faulty.
006:000 or
• HV Circuit failure.
006:001 ~ 255
• Power supply fails.
007:000 or
• IC1203,1204 (A board) faulty.
007:001 ~ 255
•Discharge CRT
101:000 or
(CR, CG, CB boards)
101:001 ~ 255
• Static discharge
• External noise
– 5 –
KP-FS57M31/M61/M90/M91
Detected Symptoms
• Power does not come on.
• No power is supplied to the PJ.
• AC power supply is faulty.
• Power does not come on.
• Load on power line is shorted.
• +135V is too high.
• Vertical deflection pulse is
stopped.
• Vertical size is too small.
• Vertical deflection stopped.
• No raster is generated.
• CRT cathode current detection
reference pulse output is small.
• Abnormal High voltage.
• Abnormal H.drive.
• +5v down.
• There is picture but speaker does
not release sound.
• Power is shut down shortly, after
this return back to normal.
• Detect Micro latch up.
RM-997