(10) Mount the PF latch 2 onto PF shaft from the receipt
side, and the PF roller assembly from the journal side.
PF latch 2
Apply Mobile 1
PF clutch spring 2
(Apply Moly LG-S No. 1
to outer circumference)
PF clutch spring
(Apply Moly LG-S No. 1
to outer circumference)
(11) Engage the PF roller assembly, PF latch and PF latch
2 with PF clutch spring and PF clutch spring 2,
respectively.
Note:
There are protrusions at both ends of the
PF clutch springs. Match these to the slits
on the PF roller assembly and the PF latch.
Slit
PF latch
(PF latch 2)
PF clutch spring
(PF clutch spring 2)
Protrusion
PF latch
Apply Mobile 1
PF roller assembly
Protrusion
PF roller assembly
Slit
(12) Insert the PF shaft assembly into the PF housing
and apply ORELUBE G-1/3 to the left and right
fixing lever (L)and (R).
Note:
When mounting the PF shaft assembly,
match the PF roller assembly and PF latch
position to the platen width of the PF
housing.
Apply ORELUBE G-1/3
PF shaft assembly
Platen
12
Apply ORELUBE G-1/3
PF housing