Panasonic KX-TG1711MEB Service Manual page 39

Dect 6.0 digital cordless phone, caller id compatible
Hide thumbs Also See for KX-TG1711MEB:
Table of Contents

Advertisement

11.4.2.2. Batch file Setting
1.
Insert the Batch file CD-ROM into CD-ROM drive and
copy PNZZTG***** folder to your PC (example: D drive).
2.
Open a window of MS-DOS mode.
3.
At the DOS prompt, type "D:" (for example) to select the
drive, then press the Enter key.
4.
Type "CD PNZZTG*****", then press the Enter key.
5.
Type "CTE open com X", then press the Enter key
(X: COM port number used for the serial connection on your PC).
6.
Type "READID", then press the Enter key.
If any error messages appear, change the port number or
check the cable connection.
If any value appear, go to next step.
7.
Type "DOSKEY", then press the Enter key.
Note:
• "*****" varies depending on the country.
11.4.2.3. Commands
See the table below for frequently used commands.
Command name
rdeep
Read the data of EEPROM
readid
Read ID (RFPI)
writeid
Write ID (RFPI)
setfreq
adjust Frequency of RFIC
Getchk
Read checksum
wrteep
write eeprom
On your computer, click [Start], select Programs
(All Programs for Windows XP/Windows Server 2003),
then click
MS-DOS Prompt. (for Windows 95/Windows 98)
Or
Accessories-MS-DOS Prompt. (for Windows Me)
Or
Command Prompt. (for Windows NT 4.0)
Or
Accessories-Command Prompt.
(for Windows 2000/Windows XP/Windows Server 2003)
Function
Type "rdeep 00 00 10", and the data from address "00 00" to "10" is read
out.
Type "readid", and the registered ID is read out.
Type "writeid 00 18 E0 0E 98", and the ID "0018 E0 0E 98" is written.
Type "setfreq nn nn".
Type "getchk".
Type "wrteep 01 23 45". "01 23" is address and "45" is data to be written.
39
KX-TG1711MEB/KX-TG1712MEB/KX-TGA171MEB
<Example for Windows>
<Example: correct setting>
C: Documents and Settings>D:
D: >CD PNZZTG*****
D: PNZZTG***** >CTE open com X
D: PNZZTG*****>READID
00 52 4F A8 A8
D: PNZZTG*****>DOSKEY
D: PNZZTG*****>
<Example: incorrect setting>
C: Documents and Settings>D:
D: >CD PNZZTG*****
D: PNZZTG***** >CTE open com X
D: PNZZTG*****>READID
ReadID
ReadIPUI Error: read access failed
D: PNZZTG*****>
Example