KX-TG1711MEB/KX-TG1712MEB/KX-TGA171MEB

11.2. Adjustment Standard (Base Unit)

When connecting the simulator equipment for checking, please refer to below.
11.2.1. Bottom View
OSC
LOOP
AF VOLT
Simulator
METER
BELL
Simulator
Call - ID
Simulator
DTMF
Tester
Frequency
Counter
Note:
(A) - (O) is referred to Check Point (Base Unit) (P.24)
AF
OSC
600
L1R
L1T
YLW
BLK
BRN
RED
GRY PUR
L1T
L1R
DCM
DCP
P1.0
LINE_DC
Charge
Charge+
12
2W
Digital
Digital
Volt Meter
Volt Meter
36
OSC
AF VOLT
METER
MIC
SP
150
Dummy Handset
TP3
RXD
TXD
GND
DC_IN
VDD
TP4
Digital
Volt Meter
AF
OSC
ANT
DECT Tester
GND
CTS60
PC
RXD
TXD
Serial
JIG
GND
DC_IN
DC POWER
DC 6.5V
GND