STANDARD CIRCUIT DIAGRAM

NOTE ON USING CIRCUIT DIAGRAMS
1. SAFETY
The components identified by the ! ! ! ! ! symbol and shading are
critical for safety. For continued safety replace safety critical
components only with manufactures recommended parts.
2. SPECIFIED VOLTAGE AND WAVEFORM VALUES
The voltage and waveform values have been measured under the
following conditions.
(1) Input signal
(2) Setting positions of each knob/button and variable resistor
(3) Internal resistance of tester : DC 20k /V
(4) Oscilloscope sweeping time : H
(5) Voltage values
* Since the voltage values of signal circuit vary to some extent
according to adjustments, use them as reference values.
3. INDICATION OF PARTS SYMBOL [EXAMPLE]
In the PW board
: R1209
4. INDICATIONS ON THE CIRCUIT DIAGRAM
(1) Resistors
Resistance value
No unit
: [ ]
K
: [K ]
M
: [M ]
Rated allowable power
No indication
: 1/4 [W]
Others
: As specified
Type
No indication
: Carbon resistor
OMR
: Oxide metal film resistor
MFR
: Metal film resistor
MPR
: Metal plate resistor
UNFR
: Non-flammable resistor
FR
: Fusible resistor
* Composition resistor 1/2 [W] is specified as 1/2S or Comp.
(2) Capacitors
Capacitance value
1 or higher
: [pF]
less than 1
: [ F]
Withstand voltage
No indication
: DC50 [V]
AC indicated
: AC withstand voltage [V]
Others
: DC withstand voltage [V]
* Electrolytic Capacitors
47/50 [Example]: Capacitance value [ F]/withstand voltage [V]
: Colour bar signal
: Original setting position when
shipped
20 S/div
: V
5mS/div
: Others
Sweeping time is
specified.
: All DC voltage values
R209
Type
No indication
MY
MM
PP
MPP
MF
TF
BP
TAN
(3) Coils
No unit
Others
(4) Power Supply
* Respective voltage values are indicated.
(5) Test point
(6) Connecting method
(7) Ground symbol
: LIVE side ground
#
: ISOLATED (NEUTRAL) side ground
"
: EARTH ground
: DIGITAL ground
5. NOTE FOR REPAIRING SERVICE
This model's power circuit is partly different in the GND. The differ-
ence of the GND is shown by the LIVE : (#) side GND and the
ISOLATED (NEUTRAL) : (") side GND. Therefore, care must be
taken for the following points.
(1) Do not touch the LIVE side GND or the LIVE side GND and the
ISOLATED (NEUTRAL) side GND simultaneously. If the above
caution is not respected, an electric shock may be caused.
Therefore, make sure that the power cord is surely removed from
the receptacle when, for example, the chassis is pulled out.
(2) Do not short between the LIVE side GND and ISOLATED (NEU-
TRAL) side GND or never measure with a measuring apparatus
(oscilloscope, etc.) the LIVE side GND and ISOLATED (NEU-
TRAL) side GND at the same time. If the above precaution is
not respected , a fuse or any parts will be broken.
Since the circuit diagram is a standard one, the circuit and
circuit constants may be subject to change for improvement
without any notice.
No. 56077
: Ceramic capacitor
: Mylar capacitor
: Metalized mylar capacitor
: Polypropylene capacitor
: Metalized polypropylene capacitor
: Metalized film capacitor
: Thin film capacitor
: Bipolar electrolytic capacitor
: Tantalum capacitor
: [ H]
: As specified
: B1
: 12V
: 9V
: 5V
: Test point
: Only test point display
: Connector
: Wrapping or soldering
: Receptacle
AV-14FT
2-3