I. TECHNICAL SPECIFICATION & SAFETY
PRECAUTIONS
POWER SUPPLY: AC 150-250V, 50 Hz
* Tuning system: voltage synthesized type autosearch fine tuning system
* Power consumption: ¡Ü120W
* Antenna input impedance: 75¦¸
* Receiving system:
a) Color system: PAL/SECAM/NTSC3.58MHZ/4.43MHZ
b) Broadcast TV system: D/K, B/G, I, M
* Language displayed: English/Russian
* Video input: 1.0VPP (75¦¸)
* Video output: 1.0VPP (75¦¸)
* Audio input: 436m Vrms (40K¦¸)
* Audio output: 436m Vrms (more than 600K¦¸)

SAFETY PRECAUTIONS

INPORTANT SAFETY NOTICE
These parts are identified by many electrical and mechanical parts in this chassis have
special safetyrelated characteristics. ! in the Schematic Diagram and Replacement
Parts List.
It is essential that these special safety parts should be replaced with the same
components as recommended in this manual to prevent XRADIATION, Shock, Fire, or
other Hazards.
Do not modify the original design without permission of the manufacturer.
General Guidance
An Isolation Transformer should always be used during the servicing of a receiver whose
chassis is not isolated from the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents that might result in personal injury
caused by electrical shocks.
It will also protect the receiver and it's components from being damaged by accidental
shorts of the circuitry that might be inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this TV receiver is blown, replace it with a specified
one.
When replacing a high wattage resistor (Oxide Metal Film Resistor, over 1W), keep the
resistor 10mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Due to the high vacuum and large surface area of the picture tube, extreme care should
be taken in handling the Picture Tube. Do not lift the Picture Tube by its Neck.
X-RAY Radiation
Warning:
The source of XRAY RADIATION in this TV receiver is the High Voltage Section and the
Picture Tube.
For continued XRAY RADIATION protection, the replacement tube must be of the same
type as specified in the Replacement Parts List.
Before returning the receiver to the customer
Always perform an AC leakage current check on the exposed metallic parts of the
cabinet, such as antennas, terminals, etc., to make sure that the set is safe to operate
without any danger of electrical shock.