Disconnecting the battery cables:
1. Stop the engine.
2. Disconnect the negative (-) battery cable from the generator negative (-)
terminal.
3. Disconnect the other end of the negative (-) battery cable from the battery
negative (-) terminal.
4. Disconnect the positive (+) battery cable from the generator positive (+)
terminal.
5. Disconnect the other end of the positive (+) battery cable to the battery
positive (+) terminal.
6. Connect the vehicle ground cable to the battery negative (-) terminal.
DC TERMINAL
(RED)
DC TERMINAL
(BLACK)