Kenwood TK-2200 Service Manual page 27

Hide thumbs Also See for TK-2200:
Table of Contents

Advertisement

Receiver Section
Item
Condition
1.BPF Wave
(1)Center frequency
Adjust
Spectrum analyzer setting analyzer
Center-f : 162MHz
Span : 100MHz
RBW : 100kHz
VBW : 10kHz
ATT
: 5dB
(2)High-edge frequency
Spectrum analyzer setting
Center-f : 174MHz
(3)Low-edge frequency
Spectrum analyzer setting
Center-f : 150MHz
2.Sensitivity
TEST CH: Low
check
Center
[Wide]
High
SSG otuput:–117 dBm(0.3µV) AF VTVM
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.SQL1
TEST CH: Center
(Threshold)
Low
writing
High
[Wide]
SSG otuput:–123 dBm(0.16µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–122 dBm(0.18µV)
SSG MOD:1.5kHz
4.SQL9
TEST CH: Center
(Tight)
Low
writing
High
[Wide]
SSG otuput:–117 dBm(0.3µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH:Center
SSG otuput:–116 dBm(0.35µV)
SSG MOD:1.5kHz
5.BATT
BATT terminal voltage:5.9V
Detection
Writing
ADJUSTMENT
Measurement
Test equipment
Terminal
Spectrum
ANT
BPF
SSG
ANT
DVM
Oscilloscope
DVM
ANT
BATT terminal
TK-2200
Adjustment
Parts
Method
Programming
Adjust the
Software:
waveform as
KPG-88D
shown to the
right.
Check
Programming
Write
Software:
KPG-88D
Write
Specifications/
Remark
REF -6.7 dBm
10dB/ A_Write Norm B_Blank Norm
CENTER
162.0 MHz
CENTER 162.0 MHz
SPAN 100.0 MHz
∗RBW 100 kHz ∗VBW 10 kHz ∗SWP 200 ms ATT 5 dB
REF -6.7 dBm
10dB/ A_Write Norm B_Blank Norm
CENTER
174.0 MHz
CENTER 174.0 MHz
SPAN 100.0 MHz
∗RBW 100 kHz ∗VBW 10 kHz ∗SWP 200 ms ATT 5 dB
REF -6.7 dBm
10dB/ A_Write Norm B_Blank Norm
CENTER
150.0 MHz
CENTER 150.0 MHz
SPAN 100.0 MHz
∗RBW 100 kHz ∗VBW 10 kHz ∗SWP 200 ms ATT 5 dB
12dB SINAD or more
Squelch open
BATT terminal
voltage:5.9V
27