Unpacking; Service; Description; Alarm Capacities - Bosch LTC 8713 Series Instruction Manual

Alarm port expanders
Hide thumbs Also See for LTC 8713 Series:
Table of Contents

Advertisement

LTC 8713 Series | Instruction Manual | Unpacking
1

UNPACKING

Unpack carefully. This is electronic equipment and
should be handled carefully.
Check for the following items:
Verify the unit model number.
One (1) cable assembly with 9-pin D-sub
connectors.
If an item appears to have been damaged in shipment,
replace it properly in its carton and notify the shipper.
If any items are missing, notify your Bosch Security
Systems, Inc. Sales Representative or Customer

Service.

The shipping carton is the safest container in which the
unit may be transported. Save it for possible future use.
2
SERVICE
If the unit ever needs repair service, the customer
should contact the nearest Bosch Security Systems, Inc.
Service Center for authorization to return and shipping
instructions.
Service Centers
USA: Phone:
800-366-2283 or 717-735-6638
fax:
800-366-1329 or 717-735-6639
CCTV Spare Parts
Phone:
800-894-5215 or 408-956-3853 or 3854
fax:
408-957-3198
e-Mail:
BoschCCTVparts@ca.slr.com
Canada:
514-738-2434
Europe, Middle East & Asia Pacific Region:
32-1-440-0711
For additional information, see
www.boschsecuritysystems.com.
WARNING: Electrostatic-sensitive
device. Use proper CMOS/
MOSFET handling precautions to
avoid electrostatic discharge.
NOTE: Grounded wrist straps must be worn and
proper ESD safety precautions observed when
handling the electrostatic-sensitive printed circuit
boards.
Bosch Security Systems | 02 February 2004
3
The LTC 8713 Series Alarm Port Expanders are used to
interface multiple LTC 8540/00 Alarm Interface Units
with an the Allegiant
system.
A single LTC 8713 Series Alarm Port Expander
supports up to four LTC 8540/00 Alarm Interface
Units. This provides the capability for up to 256 alarm
input points. Multiple LTC 8713 units may be
combined to provide up to 1024 alarm input points
using up to sixteen LTC 8540/00 units. The actual
number of units that can be used in a system depends
upon the model of the Allegiant system being used.
See Alarm Capacities table listing maximum number of
LTC 8713 series units and LTC 8540/00 units that can
be used with each Allegiant series system model.
3.1

Alarm Capacities

Allegiant
System
1
Model
LTC 8500
LTC 8600
LTC 8800
LTC 8900
1
The capacities shown apply to Allegiant CPU modules
containing software revision 7.1 or later.
ATTENTION
OBSERVE PRECAUTIONS
FOR HANDLING
ELECTROSTATIC
SENSITIVE
DEVICES

DESCRIPTION

®
series matrix switcher/controller
Maximum
Maximum
Number of
Number of
Alarms
LTC 8713
128
1
512
3
1024
5
1024
5
EN | 7
Maximum
Number of
LTC 8540/00
2
8
16
16

Advertisement

Table of Contents
loading

Table of Contents