Website: http://biz.lgservice.com LIGHT OVEN “SolarDOM” SERVICE MANUAL MODEL: MP-9483SL CAUTION BEFORE SERVICING THE UNIT, READ THE SAFETY PRECAUTIONS IN THIS MANUAL. April, 2005 P/NO : 3828W5S4913 Printed in Korea...
SAFETY PRECAUTIONS This device is to be serviced only by properly qualified service personnel. Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be taken to avoid possible exposure to excessive microwave energy. PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...
SPECIFICATIONS ITEM DESCRIPTION MODEL MP-9483SL Power Requirement 240 Volts AC 50 Hz Single phase, 3 wire grounded Microwave 1600W Grill Max 2250W Combination Max 3000W Convection 1980W Power Output 900 Watts full microwave power (IEC60705) Microwave Frequency 2450 MHz Magnetron...
CAUTIONS Unlike other appliances, the microwave oven is MICROWAVE RADIATION high-voltage and high-current equipment. Personnel should not be exposed to the Though it is free from danger in ordinary use, microwave energy which may radiate from the extreme care should be taken during repair. magnetron or other microwave generating device if it is improperly used or connection.
INSTALLATIONS BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY. INSTALLING EARTHING INSTRUCTIONS 1. Empty the oven and clean inside it with a soft, This oven is designed to be used in a fully earthed damp cloth. Check for damage such as misaligned condition.
OPERATING INSTRUCTIONS FEATURES Oven Front Plate Control Panel Deco. Window Door Screen Control Panel Door Frame Choke Cover Safety Door Lock System HIGH Rack LOW Rack Metal Tray CONTROL PANEL Speed Speed Stop Start Clock Grill Conv. Combi Auto Cook Enter Defrost Favorite...
OPERATING SEQUENCE The following is a description of component functions 6. SPEEDCOMBI COOKING during oven operation. *Speed Combi Categories Grill-1 + Microwave Power Level Co-1 1. SETTING THE CLOCK Grill-2 + Microwave Power Level Co-2 Turn Dial Grill-3 + Microwave Power Level Co-3 Stop/Clear Clock...
CIRCUIT DESCRIPTION GENERAL DETAILS power of oven as POWER LEVEL. (refer to page 1-1) • One complete cycle of relay 4 is 32 seconds. • The low voltage transformer supplies the necessary voltage to the micom controller when power cord is WHEN THE DOOR IS OPENED DURING plugged in.
SERVICE INFORMATION TOOLS AND MEASURING INSTRUMENTS NECESSARY TOOLS NECESSARY MEASURING INSTRUMENTS Tools normally used for TV servicing are sufficient. • TESTER(VOLTS-DC, AC., Ohmmeter) Standard tools are listed below. • Microwave survey meter • Diagonal pliers - Holaday HI-1500 • Long nose pliers HI-1501 •...
MEASUREMENT WITH OUTER CASE NOTES WHEN MEASURING REMOVED • Do not exceed meter full scale deflection. • The test probe must be removed no faster than • When you replace the magnetron, measure for 1 inch/sec (2.5 cm/sec) along the shaded area, microwave energy leakage before the outer case is otherwise a false reading may result.
MEASUREMENT OF MICROWAVE POWER OUTPUT • Microwave power output measurement is made with • The microwave power output P in watts is calculated the oven supplied at its rated voltage and operated from the following formula : at its maximum microwave power setting with a load 4187 x (∆T) + 0.55 X (T )X M...
Page 14
D. DOOR GROSS ASSEMBLY REMOVAL F. AIR GUIDE ASSEMBLY REMOVAL 1) Disconnect power. 1) Remove the screw on the Bracket upper and lift out 2) Open the door from oven. insert “JIG” into the choke the Bracket upper. cover hole of door. 2) Remove the mounting screw from magnetron, 3) Lift the door from front cavity.
Page 15
H. FAN MOTOR ASSEMBLY REMOVAL J. REMOVING THE TURNTABLE MOTOR 1) Remove controller assembly, air-guide, power cord, 1) Remove the metal tray. latch board-R from upper. 2) Remove the turntable shaft VERY CAREFULLY. 2) Disconnect the leadwire from fan motor, latch board-R 3) Lay the unit down on its back.
Page 16
K. C-MOTOR, THERMISTOR REMOVAL PCB Bracket PCB Sub (Main) 1) Remove air-guide and controller assembly upper. PCB Holder 2) Disconnect the leadwire from the circulation motor PCB Sub terminal and oven thermostat. (Tact S/W) 3) Remove the screws of the thermistor, guide assy- Control Panel chamber and lift up the guide assy-chamber.
Page 17
N. UPPER HEATER REMOVAL O. LOWER HEATER REMOVAL 1) Remove the screw securing the air-guide to the 1) Disconnect the leadwire from the sheath heater. upper. 2) Remove the base plate from cavity. 2) Disconnect the leadwire from the sheath heater 3) Remove the nuts from the oven cavity of the side.
INTERLOCK CONTINUITY TEST WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS. TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH A.
COMPONENT TEST PROCEDURE CAUTIONS 1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE HIGH VOLTAGE TRANSFORMER.
COMPONENTS TEST PROCEDURE RESULTS Antenna Gasket Chassis Filament NOTE: When testing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition. HIGH VOLTAGE Measure the resistance. Normal: Momentarily indicates CAPACITOR (Ohm-meter scale: Rx1000) several ohms, and then...
Page 21
COMPONENTS TEST PROCEDURE RESULTS FUSE Check for continuity of the fuse with an Normal Abnormal H.V. FUSE multi-meter. NOTE: If the fuse is blown, check the primary, the secondary, and the monitor switches, H.V.D. and H.V.C. before replacing the fuse. If the fuse is blown by improper switch operation replace the defective switch and the fuse at the same time.
Page 22
COMPONENTS TEST PROCEDURE RESULTS Disconnect the 4 pin Check for P.C.B. connector. Cooking Start connector from P.C.B. (Refer to schemetic diagram) 1 2 3 4 Cooking Start RELAY OF P.C.B. (Wire leads removed.) Note: Relay Relay 1: Fan motor Circulation motor Relay 2: Oven lamp Turntable motor Relay 3: P.T.C Relay...
Page 23
COMPONENTS TEST PROCEDURE RESULTS CIRCULATION MOTOR Measure the resistance. Normal : Approx.165 ohm. (Wire leads removed) (Multi-meter scale :R x 1) Abnormal : Infinite or several ohm. Check continuity between switch KEY PCB Key P.C.B. Main P.C.B terminals, by pressing an appropriate pad on key board.
TROUBLE SHOOTING WHEN YOU GET A COMPLAINT FROM YOUR CUSTOMER, EVALUATE THE COMPLAINT CAREFULLY. IF THE FOLLOWING SYMPTOMS APPLY, PLEASE INSTRUCT THE CUSTOMER IN THE PROPER USE OF THE OVEN. THIS CAN ELIMINATE AN UNNECESSARY SERVICE CALL. CAUTIONS 1. Check grounding before checking for trouble. 2.
Page 25
(TROUBLE 1) The following visual conditions indicate a probable defective control circuit. 1. Incomplete segments. • Segment missing. • Partial segment missing. • Digit flickering (NOTE: Slight flickering is normal.) 2. Colon does not turn on or blink. 3. A distinct change in the brightness of one or more numbers in display. 4.
Page 26
(TROUBLE 2) Oven does not operate at all ; Display window does not display any figures and no input is accepted. CONDITION CHECK RESULT CAUSE REMEDY Replace primary Malfunction of the Check continuity 1. Fuse blows. Continuity. and monitor monitor switch. of monitor switches.
Page 27
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired program times are set and START button is touched. CONDITION CHECK RESULT CAUSE REMEDY Defective Replace Check continuity 1.Setting time does No continuity. secondary switch secondary switch of secondary not count down...
Page 28
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run (Display operates properly) CONDITION CHECK RESULT CAUSE REMEDY No microwave Disconnect the Defective P.C.B Replace P.C.B No continuity. assembly oscillation. wire leads from assembly relay 4 and check continuity Continuity.
Page 29
(TROUBLE 6) Oven does not cook properly when programmed for the set power level (Operates properly on HIGH) CONDITION CHECK RESULT CAUSE REMEDY Output is full when Defective P.C.B. Replace P.C.B. Disconnect the Abnormal. you set lower assembly. assembly. wire leads from power level.