7-4. TRUBLE SHOOTING
• Replace PCB when no trouble after checking the contents of trouble.
CLASSIFICATION
STATE OF TROUBLE
POWER SOURCE
1. All the DISPLAY
is poor
LED OFF
2. DISPLAY LED
represents abnormal
operation.
COOLING is poor
NO COOLING
FREEZER
TEMPERATURE is poor
POINT BE CHECKED
CHECKING METHOD
1. FREEZER/
FREEZER/REFRIGERATOR
REFRIGERATOR
DOOR OPEN
2. LAMP is dim.
CHECK with the naked.
3. The connection of
Certify connection of
CONNECTOR of MAIN PWB. CONNECTOR.
1. COMPRESSOR operates?
PRESS TEST KEY on MAIN
PWB once. (forced COOLING)
•If pass less than 7 minutes
after stop of COMP, don't
press it and stand-by.
2. Whether refrigerant leaks or
Measure the amount of frost
leaks or not.
sticking on EVA and the
surface temperature of
condenser pipe.
1. Whether FAN MOTOR
PRESS TEST KEY on
operates or not.
MAIN PWB once.
(forced COOLING)
2. DEFROSTING normal?
Certify the amount of frost
sticking on EVA.
3. SENSOR normal?
Check resistance the
SENSOR in the
Refrigerator
CONTENT
POWER SOURCE is poor
Certify Fuse.
Certify outlet Voltage.
Applied voltage mistake
Use boosting TRANS.
CONNECTOR connection
Reconnect CONNECTOR.
is poor.
TRANS FUSE open.
Replace TRANS.
COMPRESSOR lock or
Replace COMPRESSOR.
blocked.
OLP, PTC is poor.
Replace OLP, PTC.
COMPRESSOR RELAY is
Replace MAIN PWB RY1
poor
THE CONNECTING WIRE
Certify the black wire of MAIN
is poor.
PWB CONNECTOR (CON2)
Refrigerant leakage.
Remedy the leaking part
and reaching Refrigerant.
FAN MOTOR is poor
Replace FAN MOTOR.
DOOR LINE contact.
Replace DOOR LINER.
CONETTING WIRE is poor.
Certify MOTOR and the
connection of the black wire
of MAIN PWB CONNECTOR.
(CON2)
DEFROSTING is poor.
See the DEFROSTING
trouble.
SENSOR RESISTANCE is
Replace SENSOR
poor.
REMEDY