SERVICING YOUR GENERATOR

SEDIMENT CUP CLEANING

1.
Turn the fuel valve lever to the OFF position and remove the key.
2.
Remove the sediment cup by turning it counterclockwise.
3.
Wash the sediment cup and O-ring in nonflammable solvent, and
dry them thoroughly.
4.
Reinstall the O-ring and sediment cup.
50
ON
Gasoline is highly flammable and
explosive.
You can be burned or seriously
injured when handling fuel.
Stop the engine and keep heat,
sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
OFF
FUEL VALVE LEVER
KEY
O-RING
SEDIMENT CUP