LG 42LG60 Manual page 7

Direct view lcd
Hide thumbs Also See for 42LG60:
Table of Contents

Advertisement

Safety and Handling and Checking Points
Safety and Handling and Checking Points
Safety and Handling Regulations
1. Approximately 20 minute pre-run time is required before any adjustments are performed.
2. Refer to the Voltage Sticker on the Switch Mode Power Supply silk screening. (+/- ½ volt).
3. Be cautious of electric shock from the Backlight section, it uses high voltage AC. Check that
the Power Supply and Drive Circuits are completely discharged because of residual current
stored before Circuit Board removal.
4. C-MOS circuits are sensitive to static electricity.
Use caution when dealing with these IC and circuits.
5. Exercise care when making voltage and waveform checks to prevent costly short circuits
from damaging the unit.
6. Be cautious of lost screws and other metal objects to prevent a possible short in the
circuitry.
Checking Points to be Considered
1. Check the appearance of the Replacement Panel and Circuit Boards for both physical damage
and part number accuracy.
2. Check the model label. Verify model names and board model matches.
3. Check details of defective condition and history. Example: Oscillator failure dead set, etc...