LG SxS GR-P247 Service Manual page 39

Table of Contents

Advertisement

EXPLATION FOR MICOM CIRCUIT
1-5. Temperature sensing circuit
1) GR-P247, L247, P207, L207
The above circuits are circuits attached to freezing room sensor or cold storage room sensor for adjusting setting
temperature at the freezing room and cold storage room, ice-making sensor for sensing water temperature in ice-making, or
an evaporator for sensing temperature of a frost removal sensor necessary for frost removal. Short or open status of every
temperature sensor is as follows:
SENSOR
Freezing sensor
Frost removal sensor
Cold storage sensor 1
Cold storage sensor 2
Ice-making sensor
Room temperature sensor
A
C
B
D
E
F
CHECK POINT
NORMAL(-30 °C ~ 50 °C)
POINT A Voltage
POINT B Voltage
POINT C Voltage
POINT D Voltage
POINT E Voltage
POINT F Voltage
- 39 -
(Sensor for freezing room)
(Sensor for frost removal)
(Sensor for cold storage room)
(Sensor for cold storage room)
IN SHORT
0.5 V~4.5 V
0 V
IN OPEN
5 V