LG SxS GR-P247 Service Manual page 35

Table of Contents

Advertisement

EXPLATION FOR MICOM CIRCUIT
1-4. Load/dispenser operation, door opening circuit
1. LOAD DRIVING CIRCUIT
✽ In even if opening the door of freezing room or cold storage room during operation of fan motor at the freezing room, this
circuit does not stop and operates at the standard RPM. In addition, if doors of freezing room or cold storage room, the
fan motor normally operates at the RPM previously operated.
✽ (A), (B), (C) and (D) of door switch for the freezing room or cold storage room are connected to the door open sensing
circuit in parallel toward both ends of switch to determine door open at MICOM.
✽ Since a door switch of the home bar is connected to door switch (C), (D) of the cold storage room, it senses door opening
if even one of both is opened.
✽ The fan motor is immediately stop if opening doors of the freezing room or cold storage room at the TEST mode and it
immediately operates if closing them.
1) GR-P247, L247, P207, L207
Type of Load
Measuring part (IC6)
ON
Status
OFF
Frost Removal
COMP
Heater
IC6-16
IC6-15
AC Converting
R-room LAMP
Relay
IC6-14
Within 1 V
12 V
- 35 -
Water Tank
Heater
IC7-13
IC7-15