GROUNDING INSTRUCTIONS (Cont.)
Do not modify the plug provided with the appliance. If it
B.
This appliance must be connected to a grounded, metal,
conductor must be run with the circuit conductors and
connected to the equipment grounding terminal or lead
on the appliance.
ELECTRICAL CONNECTION LOCATION
24" MODELS
TERMINAL
CONNECTING DRYER USING 3-WIRE
CONNECTION
SCREWS
(3)
COVER
3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit grounding
through the neutral conduction.
dryer's circuit fuse at the electrical box.
appliance cord is unplugged from the wall.
Installation Instructions
27" MODELS
GREEN
GROUND
GROUND
STRAP
SCREW
HOT
STRAIN RELIEF
WIRE
BRACKET
L 1
3/4", UL
RECOGNIZED
L 2
STRAIN RELIEF
NEUTRAL
HOT
(White)
WIRE
3 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH CLOSED
LOOP OR SPADE TERMINALS WITH
UPTURNED ENDS (NOT SUPPLIED).
A. Connect the 2 hot lines to the outer screws of the
terminal of block and to green ground screw on cabinet
7. Properly secure power cord to strain relief.
8. Reinstall the cover.
WARNING:
COVER OFF OF THE TERMINAL BLOCK.
CONNECTING APPLIANCE USING 4-WIRE
CONNECTION (MUST BE USED FOR

MOBILE HOME INSTALLATION)

NOTES: SInce January 1,1996, the National Electric code
requires that the new constructions utilize a 4-wire
connection to an electric dryer.
WARNING:
used when the appliance is installed in a location where
grounding through the neutral conductor is prohibited.
Grounding through the neutral is prohibited for the new
branch-circuit installations, mobile homes, recreational
vehicles, and areas where local codes prohibit grounding
through the neutral conduction.
REMOVE GROUND STRAP
AND DISCARD. KEEP GREEN
GROUND SCREW
SCREWS
(3)
COVER
dryer's circuit fuse at the electrical box.
receptacle.
4. Remove and discard ground strap. Keep the green
ground screw for step 7.
5
NEVER LEAVE THE
Only a 4-conductor cord shall be
HOT
WIRE
RELOCATE GREEN
GROUND SCREW
HERE
GREEN OR
L 1
YELLOW WIRE
N
STRAIN
L 2
RELIEF
BRACKET
NEUTRAL
(White)
3/4", UL
HOT
RECOGNIZED
STRAIN RELIEF
WIRE
4 #10 AWG MINIMUM COPPER
CONDUCTORS OR 120/240V 30A POWER
SUPPLY CORD KIT MARKED FOR USE
WITH DRYERS & PROVIDED WITH
CLOSED LOOP OR SPADE TERMINALS
WITH UPTURNED ENDS (NOT SUPPLIED).