Sharp R-4H55 Service Manual page 12

Microwave oven
Table of Contents

Advertisement

RdH55
RdX55
RdX55B
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
A
MAGNETRON TEST
NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL
WHILE THE OVEN IS IN OPERATION.
CARRY OUT 3D CHECKS
Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament
terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for a short circuit filament to anode condition, connect ohmmeter between one of the filament
terminals and the case of the magnetron (ground). This test should be indicated an infinite resistance.
If a low or zero resistance reading is obtained then the magnetron should be replaced.
MICROWAVE OUTPUT POWER (1 Litre water load)
The following test procedure should be carried out with the microwaveoven in a fully assembled condi-
tion (outer case fitted).Microwave output power from the magnetron can be measured by way of IEC
705, i.e. it can be measured by using water load how much it can be absorbed by the water load. To
measure the microwave output power in the microwave oven, the relation of calorie and watt is
used.When P(W) heating works for t(second), approximately P x t/4.1 87calorie is generated. On the
other hand, if the temperature of the water with V(ml) rises
AT
("C) during this microwave heating
period, the calorie of thewater is V x AT
The formula is as follows;
Pxtl4.187=VxAT
P(W)=4.187xVxAT/t
Our condition for the water load is as follows:
Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . around 20°C
Power supply Voltage . . . . . . . . . . . . . . . Rated voltage
Water load . . . . . 1000 g
Initial temperature . . . . . . . . . . . 10+2"C
Heating time . . . . . . . . . . . . . . . . . . . . . 47 sec.
P=90xAT
Measuring condition:
1. Container
The water container must be a cylindrical borosilicate glass vessel having a maximum material
thickness of 3 mm and an outside diameter of approximately 190 mm.
2. Temperature of the oven and vessel
The oven and the empty vessel are at ambient temperature prior to the start of the test.
3. Temperature of the water
The initial temperature of the water is (10 f. 2)X.
4. Select the initial and final water temperature so that the maximum difference between the final
water temperature and the ambient temperature is 5°C.
5. Select stirring devices and measuring instruments in order to minimize addition or removal of heat.
6. The graduation of the thermometer must be scaled by 0.1 "C at minimum and an accurate ther-
mometer.
7. The water load must be (1000 + 5) g.
8. "t" is measured while the microwave generator is operating at full power. Magnetron filament heat-
up time is not included.
NOTE: The operation time of the microwave oven is "t +
2" sec. 2
sec. is magnetron filament heat-up
time.
Measuring method:
1. Measure the initial temperature of the water before the water is added to the vessel.
(Example: The initial temperature Tl = 11 "C)
2. Add the 1 litre water to the vessel.
3 Place the load on the centre of the shelf.
10