7

WIRING DIAGRAM

INDOOR UNIT
PLA-A12BA4
PLA-A30BA4
[LEGEND]
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
CN2L
CONNECTOR (LOSSNAY)
CN24
CONNECTOR <BACK-UP HEATING>
CN30
CONNECTOR <LLC>
CN32
CONNECTOR (REMOTE SWITCH)
CN41
CONNECTOR (HA TERMINAL-A)
CN51
CONNECTOR (CENTRALLY CONTROL)
CN105
CONNECTOR (RADIO FREQUENCY INTERFACE)
FUSE
FUSE (T6.3AL250V)
LED1
POWER SUPPLY (I.B)
LED2
POWER SUPPLY (R.B)
LED3
TRANSMISSION (INDOOR-OUTDOOR)
SW1
SWITCH (MODEL SELECTION) See table 1
SW2
SWITCH (CAPACITY CODE) See table 2
SWE
CONNECTOR (EMERGENCY OPERATION)
X1
RELAY (DRAIN PUMP)
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
RFI
RADIO FREQUENCY INTERFACE FOR RF THERMOSTAT
<Table 2>SW2 (CAPACITY CODE)
SW2
MODELS
Service
MODELS
1 2 3 4 5
PLA-A12BA4
PLA-A30BA4
ON
OFF
1 2 3 4 5
PLA-A18BA4
PLA-A36BA4
ON
OFF
1 2 3 4 5
PLA-A24BA4
ON
PLA-A42BA4
OFF
The black square (
) indicates a switch position.
I.B
VANE CNV (WHT )
20
18
16
14
12
10
8
6
4
2
19
17
15
13
11
9
7
5
3
1
WIRELESS
1
3
CN90
CN3G
(WHT )
1
9
(BLK )
9
CNB
5
5
5
5
BZ
LED2
SW1
M
M
M
M
LED1
SW2
MV
MV
MV
MV
RU
W.B
GRILLE
Notes: 1. SymboIs used in wiring diagram above are,
2. Indoor and outdoor connecting wires are made with poIarities, make wiring matching terminal numbers (S1, S2, S3 ).
3. Since the outdoor side electric wiring may change be sure to check the outdoor unit electric wiring for servicing.
1.Use copper supply wires.
PLA-A18BA4
PLA-A36BA4
SYMBOL
MF
FAN MOTOR
MV
VANE MOTOR
TB4
TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE)
TB5,TB6
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
TH1
ROOM TEMP. THERMISTOR
(32°F / 15kΩ, 77°F / 5.4kΩ DETECT)
TH2
PIPE TEMP. THERMISTOR/LIQUID
(32°F / 15kΩ, 77°F / 5.4kΩ DETECT)
TH5
COND. / EVA. TEMP. THERMISTOR
(32°F / 15kΩ, 77°F / 5.4kΩ DETECT)
OPTION PART
W.B
PCB FOR IR WIRELESS REMOTE CONTROLLER
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
LED2
LED (PREPARATION FOR HEATING : ORANGE)
RECEIVING UNIT
RU
SW1
EMERGENCY OPERATION (HEAT / DOWN)
SW2
EMERGENCY OPERATION (COOL / UP)
R.B
WIRED REMOTE CONTROLLER BOARD
TB6
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
Service
1 2 3 4 5
Refer to tables 1 and 2
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
2 1
ON
OFF
TB6
R.B
J41
J42
CN32
SW1
SW2
(WHT )
CN51 (WHT ) CN24 (YLW )
Pair No.
5
CN41 (WHT )
CN2L
2 1
4
LED3
LED2
LED1
SWE
ON OFF
I-SEE
I-SEE
FLOAT SW
CN105
SENSOR
SENSOR MOTOR
CN4Y
CN6Y
(RED )
(WHT )
(RED )
1
4
1
6
1
5
1
5
5
4
M
FS
I-SEE
RFI
SENSOR
MT
I-SEE SENSOR
CORNER PANEL
(OPTION PART)
: Connector,
PLA-A24BA4
PLA-A42BA4
NAME
<Table 1>SW1 (MODEL SELECTION)
TB5
SW1
2
Service
1
1 2 3 4 5
ON
TRANSMISSION
OFF
WIRES
2
DC12V
1
3
1 3
INDOOR/OUTDOOR
COMMUNICATION
2
1
1
CN3C
RECTIFICATION
(BLU)
1
2
REMOCON
1
CN22
(BLU)
LIQUID/PIPE
INTAKE
FAN
CN30
CN4F
CN44
CN20
CNMF
(GRN )
(WHT )
(WHT )
(RED )
(WHT )
4
1
4
1 2
7
1
3
TH2
TH5
TH1
Be sure to turn off the source power
and then disconnect fan motor connector.
(Failure to do so will cause trouble in Fan motor)
: Terminal block .
13
YLW
ORN
1 3 5
OUTDOOR
CN01
ORN
(BLK)
BRN
FUSE
DC280V
X1
D.U.M
CNAC
CNP
4
1
3
1
1
3
(WHT )
(BLU )
M
MS
1~
3~
DP
MF
1
TB4
YLW
S1
TO
ORN
S2
OUTDOOR
UNIT
S3