PUMP
Pump Outlet Hose
Tub Pump
Bellows
HEATER
M6 heater nut
1
Remove pump outlet hose.
2
Remove tub pump bellows.
3
Remove cap (Remaining Hose.)
4
Disconnect the wiring.
5
Unscrew 2 screws.
6
Remove the pump.
• Rating : 220~240V 50HZ 30W
• Resistant : 160~177Ω
1
Loosen the M6 heater nut to pull out the
heater.
CAUTION
When mounting the heater, be sure to insert
the heater into the heater clip on the bottom
of the tub.
• Rating : 220~240V 2000W
• Resistant : 24.7~28.0Ω