Read Sector (S) Ext (X '24') - Fujitsu MHY2250BH Product/Maintenance Manual

Disk drives
Hide thumbs Also See for MHY2250BH:
Table of Contents

Advertisement

(37) READ SECTOR (S) EXT (X '24')

Description
This command is the extended command of the READ SECTOR (S) command.
The LBA specification is increased from 28 bits to 48 bits, and the maximum
number of sectors that can be transferred by a single command is changed from
100h to 10000h. Other command controls are the same as those of the READ
SECTOR (S) command.
Error reporting conditions
(1) The command was issued in CHS mode (ST = 51h, ER = 04h).
The other error reporting conditions are the same as those of the READ
SECTOR(S) command.
At command issuance (Shadow Block Registers setting contents)
CM
DH
CH EXP
CH
CL EXP
CL
SN EXP
SN
SC EXP
SC
FR EXP
FR
At command completion (Shadow Block Registers contents to be read)
ST
DH
CH EXP
CH
CL EXP
CL
SN EXP
SN
SC EXP
SC
ER
C141-E262
0
0
1
0
1
L
1
x
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
Sector count (15-8)
Sector count (7-0)
xx
xx
Status information
1
L
1
x
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
xx
xx
Error information
5.3 Host Commands
0
1
0
0
xx
xx
5-143

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents