Maintenance Schedule; H. Replacement Part List - GE Homespring Owner's Manual

Water purifier system
Hide thumbs Also See for Homespring:
Table of Contents

Advertisement

E. MAINTENANCE SCHEDULE
WARNING:
designed and tested to offer reliable service, provided if
it is installed, commissioned, operated, maintained and
tested in strict accordance to the safety instructions
contained in this manual. Failure to properly maintain
the System will compromise performance and/or
result in failure to control water quality which may
lead to delivery of contaminated water. Consuming
contaminated water could result in serious injury or
possible death.
A Homespring Authorized Technician must perform all service
and maintenance. As part of the annual maintenance, the
Homespring Authorized Technician will perform an Integrity
Test to check the condition of the System membrane and
perform a cleaning procedure to clean the System membrane.
This annual test and cleaning is mandatory as part of the
5-year limited prorated membrane warranty.
If the Homespring Authorized Technician determines that
the System has a high degree of debris and contaminants,
causing an abnormally high reduction in System flowrate,
the number of maintenance visits per year may be increased
to ensure that the System functions within its acceptable
operational parameters and to ensure that the limited
warranty remains in effect.

Maintenance Schedule

The following maintenance tasks must be performed every 12
months unless specified otherwise. Refer to:
H. REPLACEMENT PART LIST AND PROCEDURES for part numbers.
The System has been
System Part
Annual Maintenance Tasks
Replace. Water sources with
Carbon
high level of particulate and/
Prefilter
or chlorine will require more
frequent replacement.
Clean. Water sources with
Stainless Steel
high level of sediment will
Prefilter
require more frequent
cleaning.
System
Clean
Membrane
System
Perform Integrity Test
Membrane
Backpulse
Tank Air
Check and adjust
Pressure
Controller
Batteries
Replace
(2 AA)
Controller
Flushing and
Verify if settings are still
Draining
appropriate
programs
Every 6 Months: For models equipped with the Surface Water
Option Kit, the External Prefilter cartridge must be inspected,
cleaned and/or replaced.
System Membrane Cleaning
The following System cleaning procedures are performed
by the Homespring Authorized Technician during the annual
maintenance.
WARNING:
gloves must be worn during maintenance of the
System to protect your hands. At the end of the
procedure, wash your hands thoroughly with soap and
water. Do not reuse the gloves. Dispose of the gloves in
the garbage.
1
Ensure that the two Mini Ball Valves are closed (To close,
turn the handle perpendicular to the Plug/hose end). Remove
the Plug from the Inlet Mini Ball Valve by depressing the lock
ring and pulling on the Plug.
Mini Ball Valve
Lock Ring
FIGURE 6
UFC 211
UF 211
X
n/a
n/a
X
X
X
X
X
Disposable protective
The valve is OPEN when handle
is in the position shown
X
X
X
X
X
X
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Homespring ufc 211Homespring uf 211

Table of Contents