The boiler will not function directly. The automatic de-aeration programm of about
17 minutes will start after one of the three programm keys is pressed. The display
will show
and the number on the right indicates the actual water temperature of the boiler.
Check the water pressure regularly and top up the installation when neces-
sary.
The working pressure of the installation should be between 1.5 and 1.7 bar
It can take a while before all air has dis-appeared from a filled installation. Es-
pecially in the first week noises can be heard which indicate the presence of air.
The automatic air vent in the boiler will make this air disappear, which means the
water pressure will reduce during this period and therefore topping up with water
will be necessary to adjust the flow water temperature

Turning the boiler off

11
where A stand s for Automatic de-aeration programm Active
Holiday period:
Adjust the thermostat to the holiday period. See
the user thermostat manual. The hot water facility
can be switched off by means of the program key
on the control panel.
Re-setting the central heating system:
Switch off the three program keys
when these are activated.Switch off the power
supply. When the boiler is being drained one
should take into account that a part of the heating
water will remain in the boiler. When risk of frost
arises one should take care that the remaining
central heating water in the boiler does not freeze.
,
,