26-14
Function
Used to input the Software Key for the PS extension
(Purpose)
kit.
Operation/procedure
The current setup is displayed with ON or OFF.
Enter an input (20 digits) of the PS expansion kit soft key and press the
[OK] key, and the collating result is displayed with OK or NG.
(Initial screen)
(In case of OK)
Sim26-14 PS KIT KEY
Sim26-14 PS KIT KEY
PS KIT KEY
PS KIT KEY
ON
----------
----------
----------
----------
After canceling the simulation, if OK, the PS expansion kit function is
enable; if NG, the PS expansion kit function is disabled.
This setting must be reset after the simulation cancel.
* Execution is inhibited until GDI or PCL board is securely installed.
(Because the board is detected by the software.)
Note: Executable only when the PCL/PS3 is installed.
26-22
Purpose
Setting
Function
Used to set the specification (language display) for the
(Purpose)
destination.
Item
Specifications
Operation/procedure
Select the language to be used according to the table below.
This setup varies in connection with SIM 26-6 (Destination setup).
Sim26-22 LANGUAGE
LANGUAGE
0
(0:JAPANESE
1:ENG.US 2:ENG.UK
1/8 [ 0- 20]
0
Display items
0:JAPANESE
11:GREEK
1:ENG.US
12:POLISH
2:ENG.UK
13:HUNGARIAN
3:FRENCH
14:CZECH
4:GERMAN
15:RUSSIAN
5:ITALIAN
16:FINNISH
6:DUTCH
17:NORWEGIAN
7:SWEDISH
18:DANISH
8:SPANISH
19:CHINESE
9:PORTUGUESE
20:TAIWANESE
10:TURKISH
26-41
Purpose
Setting
Function
Used to set whether the automatic magnification ratio
(Purpose)
select (AMS) is always ON or not when setting the
pamphlet (center binding) function.
Item
Operation
Operation/procedure
AMS mode is set when setting the pamphlet (center binding) function.
Sim26-41 PAMPHLET
AMS MODE SET
0
(0:OFF 1:ON)
[ 0- 1]
0
(In case of NG)
Sim26-14 PS KIT KEY
OK
PS KIT KEY
----------
----------
Setting
Default
range
0-20
1
AR-M208 SIMULATION 8 - 8
Display items
0:OFF
1:ON
26-57
Purpose
Setting
Function
Used to set the model code.
(Purpose)
Item
Operation
NG
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
Sim26-57 MACHINE
MACHINE CODE
(1:AR-265G
2:AR-265FG
1/3 [
1- 6]
Display items
1:AR-265G
2:AR-265FG
3:AR-5127
4:AR:265S
5:AR-265FP
6:AR-M208
If a model different from CPM setup (22cpm or 27cpm) of BOOT is set,
a system error will occur after canceling the simulation.
43
43-1
Purpose
Setting
Function
Used to set the fusing temperature in each operation
(Purpose)
mode.
Section
Fixing (Fusing)
Item
Operation
Operation/procedure
After the mode selection, enter the adjustment value and press the
[OK] key.
(Initial screen)
Sim43-1 FUSER TEMP.
1:600dpi
2:1200dpi
3:POST CARD
Display items
1:600dpi
2:1200dpi
3:POST CARD
Content
Setting range
AMS is not set
automatically.
AMS is set automatically.
1
1
Setting range
Default
1-6
(Input screen)
Sim43-1 FUSER TEMP.
185
2:1200dpi
160
160
185
2
[140-190]
160
Content
Setting range
600dpi
155-190
1200dpi
140-190
Disabled
Postcard
155-190
Default
0-1
0
1
Default
185
185

Advertisement