Kenwood TK-2107 Service Manual page 21

Vhf fm transceiver
Hide thumbs Also See for TK-2107:
Table of Contents

Advertisement

Use the KPG-55D programming software for adjustment of the next item in PC MODE (see page 3).
Squelch Level, Transmit frequency, DQT Balance, RF Power, QT Deviation, DQT Deviation, Battery Level
Section common to the transmitter and receiver (VCO)
Item
Condition
1. Setting
1) Power supply voltage
Battery teriminal:7.5V
2. VCO lock
1) CH: TX high
voltage
2) CH: RX high
3) CH: TX low
4) CH: RX low
Receiver Section
Item
Condition
1. Band-
1) CH: RX center
pass filter
2) Tra generator output -40dBm
Connect the spectrum analyzer
to TP2 terminal.
2. AF level
1) CH: RX center
SSG output: -53dBm (501 V)
MOD: 1kHz
DEV: 3.0kHz (Wide)
3. Sensitivity
1) CH: RX center
CH: RX LO
CH: RX Hi
SSG ouput: -116dBm (0.35 V)
MOD: 1kHz
DEV: 3.0kHz (Wide)
4. Squelch
1) CH: RX center
Level
MONI: ON
(PC MODE)
2) Level 9
SSG output: -117dBm (0.32 V)
3) Level 3
SSG output: -125dBm(0.126 V)
Transmitter section
Item
Condition
1. Transmit
1) CH: TX center
frequency
PTT: ON
(PC MODE)
2. DQT/QT
1) CH: TX center
Balance
(PC MODE)
3. Power
1) CH:TX center
(PC MODE)
Battery terminal: 7.5V
PTT: ON
4. MAX DEV
1) CH: TX center
AG: 1kHz/120mV
PTT: ON
5. MIC SENS
1) CH: TX center
AG: 1kHz/12mV
6. QT DEV
1) CH: TX center
(PC MODE)
QT: 67.0Hz
7. DQT DEV
1) CH: TX center
(PC MODE)
TK-260
:K, K2
8. Battery
1) Battery terminal: 5.8V
Level
(PC MODE)
ADJUSTMENT
Measurement
Test equipment
Terminal
Digital voltmeter
CV
Measurement
Test equipment
Terminal
Tra generator
ANT
Spectrum analyzer
TP2
SSG
ANT
Oscilloscope
SP
AF. V. M
Distortion meter
Measurement
Test equipment
Terminal
Frequency
ANT
counter
Modulation
analyzer or linear
detector (LPF: 3kHz)
Oscilloscope
Power meter
Ammeter
Modulation
ANT
analyzer or linear
MIC
detector (LPF:15kHz)
Oscilloscope
AG
AF. V. M
Modulation
ANT
analyzer or linear
detector (LPF:3kHz)
Oscilloscope
AG
AF. V. M
Modulation
analyzer or linear
detector (LPF:3kHz)
Oscilloscope
Digital voltmeter
BATT
Adjustment
Parts
Method
TC1
3.8V
TC2
3.8V
Check
Adjustment
Parts
Method
TC201
Adjust the frequency so that
it becomes the spectrum
waveform shown in Fig.1.
L212
Adjust to the MAX AF level
Check
PC key
Level 9
Adjust to close the squelch.
Level 3
Adjust to close the squelch.
Adjustment
Parts
Method
PC key
Adjust to center frequency
VR500
Rectify the waveform to square
wave
Adjust it to 4.8W
VR501
Adjust it to
4.2kHz
Check
(+, - Peak whichever is Maximum)
PC key
Adjust it to
0.75kHz
PC key
Adjust it to
0.75kHz
PC key
A d j u s t s o t h a t t h e L E D
flashes.
TK-2107
Specifications/
Remarks
0.1V
0.1V
more than 0.7V
Specifications/
Remarks
SINAD: 12dB or
higher
The squelch must
be closed.
The squelch must
be closed.
Specifications/
Remarks
within
100Hz
0.1W
100Hz
2.2kHz~3.6kHz:
(Wide)
50Hz
50Hz
The LED must
flash.
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents