S-C Output Level Adjustment (Vc-207 Board); S-Y Output Level Adjustment (Vc-207 Board) - Sony DCR-TRV5 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV5:
Table of Contents

Advertisement

3. S-C Output Level Adjustment (VC-207 Board)

Set the chroma signal level of the S video output signal.
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
jack (75
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
94
Specified Value
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
Note 1: Insert a plug in the S VIDEO jack.
Note 2: Perform "Composite Output Y Level Adjustment" and "Composite
Output Chroma Level Adjustment" before this adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 94, change the data and set the burst
signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
Fig. 5-3-10
terminated)
H

4. S-Y Output Level Adjustment (VC-207 Board)

Set the Y signal level of the S video output signal.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: Insert a plug in the S VIDEO jack.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 95, change the data and set the sync
signal level (A) to the specified value.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
A
5-45
VTR stop
No signal
Y signal terminal of S VIDEO jack
(75
terminated)
Oscilloscope
D
95
A = 286 ± 6 mV (NTSC)
A = 300 ± 6 mV (PAL)
H
Fig. 5-3-11
A

Advertisement