Please study this manual carefully to familiarize yourself with the features and functions of your Airgle PurePal air cleaner. Inside you ® ® will find many helpful hints on how to use and maintain your Airgle ® PurePal properly. ® WARNING...
Air Cleaning System ® ® Unpacking Choosing a Suitable Location Connecting to Power Airgle® PurePal Components ® How the Airgle PurePal System Works ® ® Using the Control Panel Using the Remote Control Care and Maintenance of Your PurePal Air Cleaning System...
® applications, primarily for use in hospitals, medical clinics, and health care facilities. By introducing position for either spot or permanent applications. Airgle® has brought this revolutionary technology critical respiratory problems. By utilizing cHEPA, the ne t generation of CleanRoom Grade HEPA technology, the PurePal® Clean...
Page 5
Ideally, when you purchased your new Airgle® PurePal® cleaning system, you had assistance in making sure that you were purchasing enough air cleaning power for your room size. However, if pollution control, you may need to evaluate your level of air turnover.
® The art of puri cation UNPACKING Unpack your Airgle PurePal Clean Room ® ® System as follows: 1. Remove the PurePal Clean Room System from the packaging. ® 2. Do not throw the original bo and packaging away. Keep it in case you have to transport the unit again sometime in the future.
® The art of puri cation CHOOSING A SUITABLE LOCATION Now that you have unpacked your air cleaning system, where are you going to use it? Bedrooms: Does someone in your family have allergies and asthma? People with allergies and asthma sometimes have a hard sleeping as many of their symptoms worsen during the night.
Page 8
® The art of puri cation Keeping your system in your home air in that room – but probably only that room. Many people will turn on their air cleaner periodically throughout the day – we recommend that you leave it on for constant air cleaning while you are using the room– after all, air pollution never takes a break- why should your air cleaner? We have found that many people start with one air cleaning system and move it from room to room spend the most time.
® The art of puri cation CONNECTING TO POWER After selecting the location for your air cleaning system, and clearing the space around where it will Aft ft f er sele selecting sele sele stay, connect the power cord to the unit and the other end into the socket. conne onnect the p Plug type may vary...
® The art of puri cation PUREPAL CLEAN ROOM COMPONENTS ® PurePal Plus Components with Titanium Pro ® ® Showing 1 to 8 here auto) 2. Housing: The outside “bo ” for the unit. You will want to make sure that this is kept clean and that 3.
® The art of puri cation HOW THE AIRGLE PUREPAL ® ® CLEAN ROOM SYSTEM WORKS 1. Room air is drawn into the system via the rear grill 1. Room air is d large particles, and VOC that are adding to air pollution.
® The art of purifi cation USING THE CONTROL PANEL The Airgle ® System is equipped with a state-of-the-art control panel. This advanced control panel allows you to see unit status with one quick glance.
Page 13
® The art of purifi cation 1. Air Quality: The Airgle ® system is equipped with an advanced air quality monitoring sensor. The Air Quality Gauge displays the quality of the air in the room – the air you breathe. The 6 status bars indicate the quality from Unhealthy (1 bar) to Good (6 bars).
Page 14
® The art of purifi cation Control Panel details: right hand side 1. Timer: Press this button to set the timer for up to 12 hours of continuous operation. The time left displays on the left hand side of the panel. 2.
Page 15
® The art of purifi cation 5. IR: This infrared receiver is used by your remote control to change unit settings Control Setting The default setting for the unit is moderate and will be displayed as 4 bars on the control panel. This setting should meet most needs.
Page 16
Titanium Pro ® This Airgle® model, the AG900, includes the Titanium Pro® module, as indicated by the light bulb icon displayed on your control panel. The light bulb serves to indicate if your unit has the module installed, but also indicates when it is time to replace the module by blinking.
2. Change mode from manual to auto 3. Regulate fan speed 4. Set Timer The infrared receiver of the Airgle ® system is located in the right hand bottom corner of the control panel. In order to get the best signal transmission, the remote control should be pointed at the control panel when pressing any button on the remote.
® The art of purifi cation USER SERVICING INSTRUCTIONS OF YOUR PUREPAL Clean Room AIR ® CLEANING SYSTEM Your PurePal ® tasks. Filter Removal Your PurePal ® 1 pull up 2 pull out Open Rear Door...
Page 19
® The art of purifi cation when done and make sure that the rear door is Remove Filters (AG900 Model) completed closed. Cleaning the Gas & Odor Filter carbon) is not monitored by the Filter Check system. The Gas & least every two months to see if cleaning is necessary.
Page 20
® The art of purifi cation Life LCD is blinking, it means the Follow the instructions above to new ones. Press the “Reset” button on the Control Panel to reset the reset to 6 full bars. Replacing the Titanium Pro® module When “Light bulb”...
Page 21
The art of purifi cation ® Cleaning the Housing and Sensor Our unique Airgle system design includes ® for human hair and large particles. This module. ® Use your vacuum to clean the grill on the rear door. The sensor and housing can be cleaned using lukewarm water and a small amount of detergent.
Page 22
WARRANTY TIPS: Airgle Corporation off ers a Five Year Limited Warranty on the Airgle PurePal Series air cleaners. ® ® To activate your warranty, visit us on the web at www.Airgle.com/warranty...
Page 23
® AIRGLE CUSTOMER CARE (866) 777-1333 info@airgle.com Product Support Questions: Contact Airgle at (866) 501-7750 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com...