Stamina Seated Inversion Therapy System Owner's Manual

Seated inversion therapy system

Advertisement

Product May Vary Slightly From Pictured.
CAUTION:
Weight on this product should not exceed 250 lbs.
This Product is Produced Exclusively by
2040 N. Alliance, Springfield, MO 65803
www.staminaproducts.com
Customer Service
1 (800) 375-7520
Owner's
Manual
WARNING
!
Exercise can present a
h e a l t h r i s k . C o n s u l t a
physician before beginning
any exercise program with
this equipment. If you feel
faint or dizzy, immediately
d i s c o n t i n u e u s e o f t h i s
equipment. Serious bodily
i n j u r y c a n o c c u r i f t h i s
equipment is not assembled
and used correctly. Serious
bodily injury can also occur
if all instructions are not
followed. Keep others and
pets away from equipment
when in use. Always make
sure all bolts and nuts are
securely tightened prior to
each use. Follow all safety
instructions in this manual.
When calling for parts or
service, please specify
the following number :
Model#: 55-1541A
STAMINA PRODUCTS
MADE IN CHINA
©
2010 Stamina Products, Inc.
2010, 07
!

Advertisement

Table of Contents
loading

Summary of Contents for Stamina Seated Inversion Therapy System

  • Page 1 CAUTION: Weight on this product should not exceed 250 lbs. This Product is Produced Exclusively by STAMINA PRODUCTS MADE IN CHINA 2040 N. Alliance, Springfield, MO 65803 Customer Service © 2010 Stamina Products, Inc. 1 (800) 375-7520 2010, 07 www.staminaproducts.com...
  • Page 2: Table Of Contents

    9. The Seated Inversion Therapy System should not be used by persons weighing more than 250 lbs. 10. The Seated Inversion Therapy System should not be used by persons over 6 feet 6 inches tall. 11. It is recommended that you place this exercise equipment on an equipment mat.
  • Page 3: Customer Service

    Seated Inversion Therapy System To help you get started, we have pre-assembled most of your Seated Inversion Therapy System at the factory with the exception of those few parts left unassembled for shipping purposes. Simply follow the few assembly instructions set forth in this manual.
  • Page 4: Before You Begin

    BEFORE YOU BEGIN Thank you for choosing the Seated Inversion Although Stamina constructs its products with Therapy System. We take great pride in producing the finest materials and uses the highest standards this quality product and hope it will provide many...
  • Page 5: Equipment Warning & Notice Labels

    EQUIPMENT WARNING & NOTICE LABELS This chart is provided to help identify the warning and notice labels on the Seated Inversion Therapy System. Please take a moment to familiarize yourself with all of the warning and notice labels. Label is larger than actual size WARNING LABEL(64)
  • Page 6: Hardware Identification Chart

    HARDWARE IDENTIFICATION CHART This chart is provided to help identify the hardware used in the assembly process. Place the washers or the ends of the bolts or screws on the circles to check for the correct diameter. Use the small scale to check the length of the bolts and screws.
  • Page 7: Assembly Instructions

    ASSEMBLY INSTRUCTIONS Place all parts from the box in a cleared area and position them on the floor in front of you. Remove all packing materials from your area and place them back into the box. Do not dispose of the packing materials until assembly is completed.
  • Page 8 ASSEMBLY INSTRUCTIONS NOTE: Do not over tighten BUTTON HEAD BOLTS(53, 54) as the FRONT and REAR PIVOT ARMS(3, 5) must be able to pivot freely after BUTTON HEAD BOLTS(53, 54) are tightened. STEP 2 Position the SWING BAR(11) at the front of the BUMPER(37). Attach the FRONT PIVOT ARMS(3) to the FRONT FRAME(1) with BUTTON HEAD BOLTS(M12x1.75x85mm)(53) on both sides.
  • Page 9 ASSEMBLY INSTRUCTIONS STEP 6 Insert the BACK FRAME(9) into the BACK PIVOT FRAME(8) and secure BUTTON HEAD BOLTS (M8x1.25x15mm)(46). STEP 7 Refer to the Bottom View of the illustration below. Align the hook and loop material on the HINGE WEAR COVER(34) and the SEAT(32), then press them to attach together.
  • Page 10 ASSEMBLY INSTRUCTIONS STEP 9 Attach the SEAT BELT(31) to the BACK FRAME(9) with BUTTON HEAD BOLTS(M8x1.25x15mm)(46). STEP 10 Refer to the Back View of the illustration below. Align the hook and loop material on the HINGE WEAR COVER(34) and the BACK CUSHION(33), then press them to attach together. Attach the BACK CUSHION(33) to the BACK FRAME(9) with ROUND HEAD BOLTS(M6x1x15mm)(43).
  • Page 11 ASSEMBLY INSTRUCTIONS STEP 11: Insert the upper end of the HANDRAIL(35) into the FRONT FRAME(1) and secure with BUTTON HEAD BOLTS(M8x1.25x25mm)(47) and ARC WASHER(M8)(62). Do no tighten the bolt. Attach the lower end of the HANDRAIL(35) to the REAR FRAME(2) with BUTTON HEAD BOLTS(M8x1.25x15mm)(46), BUTTON HEAD BOLTS(M8x1.25x50mm)(49), and ARC WASHER(M8) (62).
  • Page 12: Operational Instructions

    OPERATIONAL INSTRUCTIONS GENERAL PRECAUTIONS 1. Do not use the Seated Inversion Therapy System alone. Always have a helper available in case assistance is needed in recovering from the decline position. 2. Make sure the SECURITY BELT(38) is attached on the Seated Inversion Therapy System properly.
  • Page 13 OPERATIONAL INSTRUCTIONS FOAM PAD USE AND LEVER ADJUSTMENT 1. Place your feet under the FOAM PADS(20) with your ankles between the FOAM PADS(20). 2. Pull the KNOB(19) and swing the LEVER(13) toward you until your ankles are comfortably yet firmly held between the FOAM PADS(20).
  • Page 14 2. Use the HANDRAILS(35) and both hands to rotate the BACK CUSHION(33) slowly backward until the inversion stopped by the SECURITY BELT(38). 3. It is recommended that the Seated Inversion Therapy System be used for five or ten minutes each morning, and again each evening.
  • Page 15: Storage

    STORAGE 1. To store the Seated Inversion Therapy System, simply keep it in a clean dry place. 2. Move the Seated Inversion Therapy System by lifting the frame and moving slowly. NOTE: Two people are required to move the Seated Inversion Therapy System.
  • Page 16: Product Parts Drawing

    PRODUCT PARTS DRAWING BACK FRONT...
  • Page 17: Parts List

    PARTS LIST PART# PART NAME Front Frame Rear Frame Front Pivot Arm Shaft Rear Pivot Arm Seat Frame Seat Frame Connecter Back pivot frame Back Frame Linkage Swing Bar Leg Adjustment Frame Lever Lever Bushing Claw Bar Spring Support Washer Retaining Cap Knob Foam Pad...
  • Page 18 PARTS LIST PART# PART NAME Bolt, Button Head (M8 x 1.25 x 40mm) Bolt, Button Head (M8 x 1.25 x 50mm) Bolt, Button Head (M8 x 1.25 x 55mm) Bolt, Button Head (M8 x 1.25 x 60mm) Bolt, Button Head (M10 x 1.5 x 45mm) Bolt, Button Head (M12 x 1.75 x 85mm) Bolt, Button Head (M12 x 1.75 x 95mm) Screw, Round Head (M4 x 6mm)
  • Page 19: Warranty

    To implement this limited warranty, send a written notice stating your name, date, and place of purchase and a brief description of the defect along with your receipt to Stamina Products, Inc. P.O. Box 1071, Springfield Missouri, USA, 65801-1071, or email us at customerservice@staminaproducts.com, or call us at 1-800-375-7520.
  • Page 20: Notes

    NOTES...
  • Page 21 NOTES...
  • Page 22: Fax/Mail Ordering Form

    FAX/MAIL ORDERING FORM Please do not return the product. For your convenience, Stamina's Customer Service Department can be reached by email at customerservice@staminaproducts.com or toll free at 1-800-375-7520 (in the U.S.). Should a part be missing or a defective part found, please call us from 7:30 A.M. to 5:00 P.M. Central Time, Monday through Thursday and 8:00 A.M.

This manual is also suitable for:

55-1541a

Table of Contents