Starter Motor - Westerbeke 5.0KW BCG-60Hz Service Manual

Gasoline generators single phase
Hide thumbs Also See for 5.0KW BCG-60Hz:
Table of Contents

Advertisement

STARTER MOTOR
NOTE: To oider spare parts, contact your WESTERBEKE dealer.
Q)
COVER
\
; /
~
o
RETAINER
/ )
/'" :----------------y
1
~
/
~ BUSHIN~
: WGEAR
:
I
I
I
I
STATIONARY GEAR ASSEMBLY
~----------------:
~TW_
RETAINER
. D.E. HOUSING
/ i
~
Ii
SCREW
/"
SCREW
STARTER DISASSEMBLY
Disconnect the wires and remove the solenoid from the
motor.
Remove the thru bolts and screws from the back of the motor
and separate the frame. This will provide access to the brush
holder assembly and the armature.
BRUSH HOLDER ASSEMBLY
C.E.
FRAME
(COVER)
Use this exploded view drawing to disassemble and
reassemble the starter motor.
The following pages describe the testing and repair of the
starter motor assembly.