Inspecting Burners - Comfort Glow CG3324NTA Owner's Operation And Installation Manual

Unvented (vent-free) natural gas log heater thermostat and variably-controlled models
Table of Contents

Advertisement

OPERATING
HEATER
Variable Manually-
Controlled Models
Continued
INSPECTING
BURNERS
24
VARIABLE CONTROL OPERATION
The variable control valve can be set to any heat setting and flame height desired, by
simply turning the control knob until that setting is attained. Even the lowest setting
provides realistic flames and glowing embers from two burners. Selecting higher
settings produces greater heat output. This results in increased heating comfort.
Do not operate heater between pilot and high.
Do not try to adjust heating levels by using the manual shutoff valve.
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
1. Press in and turn control knob clockwise
2. Turn the control knob clockwise
3. Press in control knob and turn clockwise
Shutting Off Burners Only (pilot stays lit)
1. Turn the control knob clockwise
2. Press in and turn control knob clockwise
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, page 23.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob. Now follow step 8, page 23.
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pattern. Figure 24 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This
will cause the thermocouple to cool. When the thermocouple cools, the heater will
shut down.
Thermocouple
Figure 23 - Correct Pilot
Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 24
• turn heater off (see To Turn Off Gas to Appliance [Thermostat-Controlled
Models] page 21 or [Variable Manually-Controlled Models] above)
• see Troubleshooting, pages 26 through 29
WARNING
WARNING ICON
G 001
CAUTION
WARNING ICON
G 001
to the HIGH position.
Clockwise
to the PILOT position.
Clockwise
to the OFF Position.
Clockwise
to the HIGH position.
Clockwise
to the pilot position.
Clockwise
Thermocouple
Pilot Burner
Figure 24 - Incorrect Pilot
Pilot Burner
Flame Pattern
102650

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cg3630ntaCg3630nvaCg2618nvaCg3324nva

Table of Contents