Packaged terminal air conditioner (ptac) air conditioner / heat pump / backup electric heater

Advertisement

Wall Sleeve
Adapter
Front Panel
PTAC Specifications
Product Shipping Weight (approx.) – 135 Lbs.
An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current
edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
Voltage Rating – 230V / 208V / 60 Hz / 20 Amps
Amps @ 230/208V Volts = (Cool) 5.1 / 5.3 Amps / (Backup Electric
Heater) 13.2 / 12.2 Amps / (Heat Pump) 4.5 / 4.7 Amps
Always consult local and national electric codes.
Recommended Circuit Breaker – 20 Amps
Unit equipped with 230/208V 3-wire power supply cord, NEMA plug
type 6-20P, approximately 66" long.
In order for condensate water to drain properly inside the unit, the
sleeve must be installed properly: Level from right to left with a slight
1/4" rearward pitch from the indoor side to the outdoor side as shown in
the illustration above. Refer to the Installation Instructions on the web.
The drain kit listed on the Frigidaire® PTAC Accessories page can
be used for an internal or external drain. This applies to new and
replacement installation.
New Installation
For new installation, Frigidaire® PTAC Sleeves are available and
recommended for proper installation. See accessories pages for
sleeve options.*
Standard PTAC installation requires 13-13/16" maximum wall thickness,
unless a wall sleeve is used.
If the PTAC unit protrudes more than 4", then it is suggested that it be
installed with a subbase. See accessories pages for subbase options.
USA
10200 David Taylor Drive
Charlotte, NC 28262
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
FRP12PTT2R 08/11
Packaged Terminal Air Conditioner (PTAC)
Chassis
Product Dimensions
Height
Width
Depth
Max. Wall Thickness
Manufacturer
General Electric
Amana
Trane
Friedrich
1-866-942-1567
frigidaire.com
1-866-942-1567
frigidaire.ca
© 2011 Electrolux Home Products, Inc.
FRP12PTT2R
Air Conditioner / Heat Pump / Backup Electric Heat
Accessory
Outdoor Grille
Accessory
Wall Sleeve
Wall Cutout Dimensions
16"
Height
42"
Width
13-13/16"
13-13/16"
Wall Sleeve Part Number
Metal Sleeve RAB71
Plastic Sleeve RAB77
Metal Sleeve WS900B
Replacement Installation
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep
When replacing existing PTAC with new unit, refer to Product
Wall Sleeve
Installation Guide on web to identify existing wall-sleeve manufacturer
and size compatibility. If proper installation and slope are suspect,
Standard-Depth Wall Sleeve
16 X 42 X 13-3/4-in. PXWS
then correct installation of Frigidaire® PTAC Sleeve options
recommended.
For any sleeve retrofit application, be sure that the foam seals
(factory-installed on the tube sheets) provide a good seal between
the grille and the outdoor coil tube sheets. These foam seals provide
a barrier that stops air from the inside mixing with air on the outside
(known as air recirculation).
Using Frigidaire® wall sleeve with Non-Frigidaire grille requires
installation of an Accessory Baffle Kit, which ensures a good seal
between the unit and exterior grille to prevent air recirculation. Air
recirculation is a large contributor to performance loss and premature
damage to major components.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
*See Frigidaire® PTAC accessories pages attached for optional accessories.
Rearward Slope
1/4 " Slope
Outside Wall
Inside Wall
16-5/16"
42-3/16"
Plug Type (NEMA)
6-20P
Specifications
subject to change.