9
8
7
Choke Cover
6
5
4
Figure C-6. Door Disassembly
RE-INSTALL
1. Re-install door screen to door frame by fitting two (2) tabs
of door frame to two (2) holes of door screen.
2. Re-install latch spring to the head. Re-install latch spring
to the door frame. Re-install latch head to the door frame.
3. Re-install door panel to door frame by fitting nine (9) tabs
of door frame to nine (9) holes of door panel.
4. Hold the door panel to the door frame with two (2)
screws.
5. Put sealer film on door panel. Refer to "Sealer Film"
about how to handle new one.
6. Catch two (2) pins of door panel on two (2) hole of upper
and lower oven hinges.
7. Re-install choke cover to door panel by pushing.
Note: After any service to the door;
(A) Make sure that door sensing switch and secondary
interlock switch are operating properly. (Refer to
chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through center of
latch hole.
2. Deviation of door alignment from horizontal line of cavity
face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter. (Refer to Microwave
Measurement Procedure.)
Note: The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of
microwave energy from oven cavity during cook
10
11
12
1
Putty Knife
2
Door frame
3
cycle. This function does not require that door be air-
tight, moisture (condensation)-tight or light-tight.
Therefore, occasional appearance of moisture, light
or sensing of gentle warm air movement around
oven door is not abnormal and do not of themselves,
indicate a leakage of microwave energy from oven
cavity.
PIN
DDOR PANEL
LOWER
OVEN
PIN
HINGE
Figure C-7. Door Replacement
SEALER FILM
Installation
1. Put the adhesive tape on the backing film of the sealer
film as shown in Fig. C-8.
2. Tear the backing film by pulling the adhesive tape.
3. Put the pasted side of the sealer film on the door panel
Sealer film
Figure C-8. Sealer film
29
UPPER
OVEN HINGE
CHOKE
COVER
Backing film
Adhesive tape
R-3H57