Trane 4YCY4060A Product Data page 10

Single packaged convertible gas/electric 14 seer 2 - 5 ton, 40 - 120 kbtu r-410a
Table of Contents

Advertisement

4YCY4042A1 AT 1400 NOM CFM
OD
ID
TOT
SENS CAP AT ENTERING DB TEMP
AMB
WB
CAP
72
59
40.3
34.1
63
42.0
27.7
85
67
45.3
21.8
71
48.9
15.9
59
37.6
32.9
63
39.2
26.6
95
67
42.2
20.7
71
45.6
14.8
59
34.9
31.7
63
36.4
25.4
105
67
39.2
19.6
71
42.3
13.7
59
32.2
30.5
63
33.6
24.3
115
67
36.2
18.5
71
39.0
12.6
4YCY4048A1/3 AT 1600 NOM CFM
OD
ID
TOT
SENS CAP AT ENTERING DB TEMP
AMB
WB
CAP
72
59
45.3
38.2
63
47.2
31.0
85
67
50.9
24.4
71
55.0
17.7
59
42.7
37.0
63
44.5
29.8
95
67
48.0
23.2
71
51.8
16.7
59
40.1
35.8
63
41.8
28.7
105
67
45.0
22.2
71
48.6
15.6
59
37.5
34.7
63
39.1
27.7
115
67
42.1
21.1
71
45.5
14.5
4YCY4060A1/3 AT 2000 NOM CFM
OD
ID
TOT
SENS CAP AT ENTERING DB TEMP
AMB
WB
CAP
72
59
56.5
47.6
63
58.9
38.5
85
67
63.5
30.2
71
68.5
21.9
59
53.1
46.0
63
55.4
37.0
95
67
59.7
28.8
71
64.4
20.5
59
49.7
44.5
63
51.9
35.7
105
67
55.9
27.4
71
60.3
19.1
59
46.4
43.0
63
48.3
34.2
115
67
52.1
26.0
71
56.2
17.7
Performance Data Cooling
(COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
TOTAL
75
78
80
KW
38.4
40.3
40.3
3.1
31.9
36.2
39.0
3.1
26.1
30.3
33.2
3.2
20.2
24.4
27.3
3.2
37.2
37.6
37.6
3.4
30.8
35.1
37.9
3.5
24.9
29.2
32.0
3.5
19.1
23.3
26.2
3.5
34.9
34.9
34.9
3.8
29.7
33.9
36.4
3.8
23.8
28.1
30.9
3.8
18.0
22.2
25.1
3.8
32.2
32.2
32.2
4.1
28.6
32.8
33.6
4.1
22.7
26.9
29.8
4.2
16.8
21.1
23.9
4.2
(COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
TOTAL
75
78
80
KW
42.9
45.3
45.3
3.6
35.7
40.5
43.7
3.6
29.1
33.9
37.1
3.7
22.5
27.3
30.4
3.7
41.7
42.7
42.7
3.9
34.6
39.3
42.6
4.0
28.0
32.8
36.0
4.0
21.4
26.2
29.4
4.0
40.1
40.1
40.1
4.3
33.5
38.3
41.4
4.4
27.0
31.7
34.9
4.4
20.4
25.1
28.3
4.4
37.5
37.5
37.5
4.7
32.4
37.2
39.1
4.7
25.8
30.6
33.8
4.8
19.3
24.0
27.2
4.8
(COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)
TOTAL
75
78
80
KW
53.5
56.5
56.5
4.4
44.5
50.5
54.4
4.4
36.2
42.2
46.2
4.5
27.8
33.8
37.8
4.5
52.0
53.1
53.1
4.8
43.1
49.0
53.0
4.9
34.8
40.7
44.8
5.0
26.4
32.4
36.4
5.0
49.7
49.7
49.7
5.3
41.6
47.6
51.6
5.3
33.3
39.3
43.3
5.4
25.0
31.0
35.0
5.4
46.4
46.4
46.4
5.8
40.2
46.2
48.3
5.8
32.0
37.9
41.9
5.9
23.7
29.6
33.7
5.9
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW
RATE, CFM
LOW
1225
HIGH
1575
ARI RATING FOR COOLING
CFM
CAPACITY (A) TEST
1360
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW
RATE, CFM
LOW
1400
HIGH
1800
ARI RATING FOR COOLING
CFM
CAPACITY (A) TEST
1605
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW
AIR FLOW
RATE, CFM
LOW
1750
HIGH
2250
ARI RATING FOR COOLING
CFM
CAPACITY (A) TEST
1799
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F
WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High
Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air
entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating
is the same as for cooling.
10
CAPACITY
TOTAL POWER
MULTIPLIER
MULTIPLIER
0.97
0.98
1.03
1.02
SEER
EER
42000
14.25
12.00
CAPACITY
TOTAL POWER
MULTIPLIER
MULTIPLIER
0.97
0.98
1.03
1.02
SEER
EER
48000
14.20
11.90
CAPACITY
TOTAL POWER
MULTIPLIER
MULTIPLIER
0.97
0.98
1.03
1.02
SEER
EER
58500
14.00
11.90

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents