Features
Eight Zones (Alarm)
6 Programmable for: Alarm, Entry/Exit, Access (walk through), Personal
Attack, Part Set Entry, Part Set Isolation.
1 Programmable for: Entry, Alarm, Fire, Keyswitch.
1 Fixed: Entry/Exit.
Door Sense Setting
Allows easy setting of the system without having to wait for the exit
timer to Run out.
Home Set Facility
Gives flexibility by automatically isolating pre-programmed zones,
allowing the system to be armed while the User remains inside.
Manual Isolation
The system can be tailored for any situation that arises by isolating
individual zones which have not been programmed for Home or Part Set
Isolation.
Remote P.A. Option
The Remote keypads can be programmed to give a Personal Attack
Feature, using the * and # Keys.
Specifications
Securit 802 Control Panel
Dimensions
Height
Width
Depth
Material
Weight
Mains Supply Voltage
230 V AC Nominal.
PSU Output Voltage
13.6 V Nominal.
Keypad
Keypads
Dimensions:
Height
Width
Depth
Supply Voltage
12 V.
Quiescent Current
20 mA.
Active
45 mA.
C&K SYSTEMS
Printed in NL - © 1998 C&K Systems • C&K is a Registered Trademark of C&K
Components, Inc.• Securitech is a trademark of C&K Systems • C&K is an ISO
9001 and 9002 certified company • All Rights reserved.
802(UK)/V.98.10 • Website: http://users.powernet.co.uk/cksys
: 254mm
: 195mm
: 60mm
: white, moulded polycarbonate
: 1.21 kg
: 70mm
: 120mm
: 25mm
Extension Speaker Output
For greater enhanced sounds, up to two 16 Ohm extension speakers
can be fitted.
Chime Function
Enabling this feature allows Monitoring of chosen zones while the panel
is disarmed.
Two User Codes
Main User code plus second code for children or cleaner etc.
Event Memory
Allows checking of past events.
Maximum Output Current
1 A (total).
Panel Quiescent
40 mA.
Normal operating temperature
0°C to 40°C
Humidity
10 to 90% R.H. non-condensing.
Maximum number allowed
Six.
Approvals
CE Designed to comply with BS4737 Part I, and BSEN50131-1
(Grades 1&2).
Ordering Part Number
ST 802.