29) Clean the storage bin liner, door liner, and door gasket with a neutral cleaner. Rinse
thoroughly after cleaning.
30) Move the control switch to the "ICE" position to start the automatic icemaking process.
C. Storage Bin Drain
In some conditions, slime may build up inside the storage bin drain and prevent water
from draining properly. To prevent this buildup, perform the following procedure once
every 3 months or as often as necessary for conditions.
If the storage bin drain becomes clogged, water could build up in the bin and
overflow, leading to costly water damage.
1) Move the control switch to the "OFF" position. WARNING! To reduce the risk of
electric shock, do not touch the control switch with damp hands.
2) Remove all ice from the storage bin.
3) Mix a batch of sanitizing solution by diluting 1.25 fl. oz. (37 ml or 2.5 tbs) of a
5.25% sodium hypochlorite solution (chlorine bleach) with 2.5 gallons (9.5 l) of warm
water. Using a chlorine test strip or other method, confirm that you have a concentration
of about 200 ppm.
4) Slowly pour the sanitizing solution into the storage bin.
5) After all of the solution has drained, clean the storage bin liner with a neutral cleaner.
Rinse thoroughly with clean water.
6) Move the control switch to the "ICE" position to start the automatic icemaking process.