Set-Up - American DJ DJ Spot 250 User Instructions

Table of Contents

Advertisement

DJ Spot 250™
Power Supply:
Before plugging your unit in, be sure the source
voltage in your area matches the required voltage for your American
DJ
DJ Spot 250.™ The American DJ
®
a 120v only. Because line voltage may vary from venue to venue, you
should be sure your unit voltage matches the wall outlet voltage before
attempting to operate you fixture.
DMX-512:
DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA "IN" and DATA "OUT" XLR terminals located on all DMX
fixtures (most controllers only have a DATA "OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models
of different manufactures to be linked together and operate from a
single controller, as long as all fixtures and the controller are DMX
compliant. To ensure proper DMX data transmission, when using
several DMX fixtures try to use the shortest cable path possible. The
order in which fixtures are connected in a DMX line does not influence
the DMX addressing. For example; a fixture assigned a DMX address
of 1 may be placed anywhere in a DMX line, at the beginning, at the
end, or anywhere in the middle. Therefore, the first fixture controlled
by the controller could be the last fixture in the chain. When a fixture
is assigned a DMX address of 1, the DMX controller knows to send
DATA assigned to address 1 to that unit, no matter where it is located
in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave
Operation): The DJ Spot 250™ can be controlled via DMX-512 proto-
col. The DJ Spot 250™ is a six channel DMX unit.
The DMX address is set electronically using the
controls on the side panel of the unit. Your unit and
your DMX controller require a standard 3-pin XLR
connector for data input and data output (Figure
1). If you are making your own cables, be sure to
use standard two conductor shielded cable (This
cable may be purchased at almost all professional
American DJ
- www.americandj.com - DJ Spot 250™ Instruction Manual Page 9
©
®
Set Up
DJ Spot 250
is available in
®
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
INPUT
POWER
DMX512
DMX+,DMX-,COMMON
1
DMX512 OUT
3
3-PIN XLR
2
Figure 1
SOUND
DJ Spot 250™
sound and lighting stores). Your cables should be made with a male
and female XLR connector on either end of the cable. Also remember
that DMX cable must be daisy chained and cannot be split.
Notice:
Be sure to follow figures two and three when making your own
cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable's shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR's outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
XLR Male Socket
1 Ground
2 Cold
REMOTE
INPUT
SOUND
CONTROL
INPUT
3 Hot
Figure 3
Special Note: Line Termination.
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
COMMON
DMX +
1
DMX512 IN
3
3-PIN XLR
DMX -
2
American DJ
©
®
REMOTE
INPUT
OUTPUT
CONTROL
SOUND
INPUT
POWER
DMX512
DMX+,DMX-,COMMON
COMMON
DMX +
1
DMX512 OUT
3
3
3-PIN XLR
DMX -
2
XLR Female Socket
2 Cold
1 Ground
OUTPUT
SOUND
3 Hot
When longer runs of cable are
POWER
Termination reduces signal errors and
avoids signal transmission problems
1
3
and interference. It is always advisable
to connect a DMX terminal, (Resistance
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
- www.americandj.com - DJ Spot 250™ Instruction Manual Page 10
REMOTE
INPUT
OUTPUT
CONTROL
Set Up
INPUT
POWER
Termination
avoids sign
1
1
DMX512 IN
and interfere
3
3-PIN XLR
2
2
to connect a
120 Ohm 1/4
Figure 2
and PIN 3 (
XLR Pin Configuration
Pin 1 = Ground
REMOTE
INPUT
OUTPUT
CONTROL
Pin 2 = Data Compliment (negative)
INPUT
Pin 3 = Data True (positive)
POWER
Figure 4
SOUND

Hide quick links: