Installing Cable; Connections In Nexus Network - Nexus Compass Data Installation And Operation Manual

Compass data
Table of Contents

Advertisement

2.1.2

Installing cable

The power cable is connected via a 3A fuse from the battery or at the
boats fuse panel and direct to the instrument or Server. One red and one
black power wire is included. Note, set C71 ON (see 5.5.1).
Always connect a 3 AMP fuse between Power supply and
instrument.
Screen
Black
Red
3A Fuse
2.1.3

Connections in Nexus Network

If you already have a Nexus Network i.e. a Server, it is more practical to
connect the transducer to the Server due to the single instrument cable
installation. Note, set C71 OFF (see 5.5.1).
Server
The instrument is then connected to the Server's Nexus Network terminal
(pin 5, 6, 7 and 8) or at any NEXUS instruments terminal .
From NEXUS Server or
other NEXUS
instrument
INSTALLATION
Yellow
Green
White
8
Transducer
Transducer