Customer Responsibilities
Check Safety Valve
Drain Tank
Air Filter
Air compressor pump intake
and exhaust valves
1- more frequent in dusty or humid conditions
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed air,
or moving parts. Personal injuries
can occur. Before performing any
maintenance or repair, disconnect
power source from the compressor
and bleed off all air pressure.
To ensure efficient operation and
longer life of the air compressor unit,
a routine maintenance schedule
should be prepared and followed.
The above routine maintenance
schedule is geared to an unit in a
normal working environment
operating on a daily basis. If
necessary, the schedule should be
modified to suit the conditions under
which your compressor is used. The
modifications will depend upon the
hours of operation and the working
environment. Compressor units in an
extremely dirty and/or hostile
environment will require a greater
frequency of all maintenance checks.
NOTE: See Operation section for the
location of controls.

MAINTENANCE

Before
each
use
Unit cycles
automatically when
Daily
Every
or after
40
each
hours
use
1
To Check Safety Valve
properly, over-pressurization may
occur, causing air tank rupture or
an explosion.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
To Drain Tank
1.
Set the On/Auto/Off lever to
"OFF".
2.
Pull the regulator knob out and
turn counter-clockwise to set the
outlet pressure to zero.
3.
Remove the air tool or accessory.
4.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
5.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
air tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
17 - ENG
Every
Yearly
100
hours
If the safety valve
does not work
Water will
condense in the
A13570